We at Crack4sure are committed to giving students who are preparing for the ARDMS SPI Exam the most current and reliable questions . To help people study, we've made some of our Sonography Principles and Instrumentation exam materials available for free to everyone. You can take the Free SPI Practice Test as many times as you want. The answers to the practice questions are given, and each answer is explained.

Question # 6

Which gray-scale artifact occurs when a structure attenuates less than the adjacent tissues?

A.

Enhancement

B.

Range ambiguity

C.

Refraction

D.

Shadowing

Question # 7

What occurs when the pulse repetition frequency is less than twice the Doppler shift frequency?

A.

Spectral broadening

B.

Range ambiguity

C.

Aliasing

D.

Propagation speed artifact

Question # 8

Which feature is a characteristic of write magnification?

A.

Post-processing

B.

New data acquisition

C.

Larger pixel size

D.

Decreased spatial resolution

Question # 9

What is an advantage of power Doppler over color Doppler?

A.

Accurate velocity information

B.

Increased frame rate

C.

Diminished flash artifact

D.

Less angle dependent

Question # 10

Which target group in this image of a tissue-mimicking phantom is used to evaluate axial resolution?

SPI question answer

A.

Option A

B.

Option B

C.

Option C

D.

Option D

Question # 11

In this image, which characteristics of flow are represented by the upper right side of a variance mode color map?

SPI question answer

A.

Higher velocity, laminar with a positive Doppler shift

B.

Higher velocity, laminar with a negative Doppler shift

C.

Higher velocity, turbulent with a positive Doppler shift

D.

Higher velocity, turbulent with a negative Doppler shift

Question # 12

Which color control was adjusted in color bar A to produce color bar B?

SPI question answer

A.

Baseline

B.

Scale

C.

Map

D.

Invert

Question # 13

Which outcome is an advantage of more pulses in an ensemble length?

A.

Reduced ghosting artifact

B.

Increased accuracy of velocity measurement

C.

Improved temporal resolution

D.

Increased line density

Question # 14

What is the primary determining factor of a pulsed wave transducer's fundamental frequency?

A.

Element thickness

B.

Aperture size

C.

Tissue propagation speed

D.

Transducer type

Question # 15

Which setting improves temporal resolution?

A.

Wide sector size

B.

Increased depth

C.

Multiple focal zones

D.

Low line density

Question # 16

What limits the maximum imaging depth for a given transducer?

A.

Amplitude

B.

Frequency

C.

Propagation speed

D.

Focal depth

Question # 17

Which statement describes the purpose of using a spectral Doppler wall filter?

A.

To widen the area in which the Doppler shift is sampled

B.

To clean up the audio signals

C.

To eliminate the higher velocity signals

D.

To eliminate the lower velocity signals

Question # 18

Which artifact causes a reflector to be improperly positioned on the display?

A.

Acoustic shadowing

B.

Speckle

C.

Enhancement

D.

Range ambiguity

Question # 19

Which adjustment follows the ALARA (As Low As Reasonably Achievable) principle of patient safety?

A.

Increase sector width

B.

Decrease depth

C.

Increase number of focal zones

D.

Decrease output power

Question # 20

What is the term for an ultrasound system's ability to display low-level echoes?

A.

Slice thickness

B.

Axial resolution

C.

Sensitivity

D.

Lateral resolution

Question # 21

Which factor affects lateral resolution in ultrasound?

A.

Beam width

B.

Depth of penetration

C.

Propagation speed

D.

Wavelength

Question # 22

What is the result of increased transducer damping?

A.

Longer pulse length

B.

Increased sensitivity

C.

Narrow beam width

D.

Improved axial resolution

Question # 23

Which pulsed-wave Doppler adjustment would be appropriate to correct the aliasing seen in this image?

SPI question answer

A.

Increase the spectral Doppler gain.

B.

Decrease the spectral Doppler gain.

C.

Increase the Doppler pulse repetition frequency.

D.

Decrease the Doppler pulse repetition frequency.

Question # 24

Which settings will lead to the highest temporal resolution?

A.

45-degree sector width, 4 cm scan depth, color Doppler off

B.

60-degree sector width, 5 cm scan depth, color Doppler off

C.

45-degree sector width, 4 cm scan depth, color Doppler on

D.

60-degree sector width, 5 cm scan depth, color Doppler on

Question # 25

How can the spectral Doppler mirroring seen in this image be eliminated?

SPI question answer

A.

Decrease wall filter.

B.

Decrease Doppler gain.

C.

Increase dynamic range.

D.

Increase pulse repetition frequency (PRF).

Question # 26

Which artifact is caused by defects in the crystals of the transducer?

A.

Mirror image

B.

Ringdown

C.

Side lobe

D.

Dropout

Question # 27

Which color Doppler control allows for reassignment of red and blue to represent flow direction?

A.

Color priority

B.

Color gain

C.

Color threshold

D.

Color invert

Question # 28

What are two types of cavitation in tissue?

A.

Heat and transient

B.

Thermal and mechanical

C.

Stable and transient

D.

Thermal and stable

Question # 29

Which change can be made in order to avoid exceeding the Nyquist limit?

A.

Increase output power

B.

Decrease output power

C.

Increase pulse repetition frequency

D.

Decrease pulse repetition frequency

Question # 30

Which will affect the gray-scale of a 2-D image?

A.

Doppler gain

B.

Depth of field

C.

Pulse repetition frequency (PRF)

D.

Dynamic range

Question # 31

What results from increasing the packet length when using color Doppler imaging?

A.

Decreased penetration

B.

Increased aliasing

C.

Increased color noise

D.

Decreased frame rate

Question # 32

What is the primary interaction that occurs when sound waves encounter a smooth, flat surface?

A.

Attenuation

B.

Reflection

C.

Diffraction

D.

Interference

Question # 33

Which unfocused transducer will have the greatest divergence?

A.

4 mm aperture, 4 MHz

B.

4 mm aperture, 6 MHz

C.

6 mm aperture, 4 MHz

D.

6 mm aperture, 6 MHz

Question # 34

Which effect does spatial compounding have on ultrasound images?

A.

Increases propagation speed

B.

Decreases propagation speed

C.

Increases shadowing

D.

Decreases shadowing

Question # 35

Which control should a sonographer use to change contrast resolution?

A.

Reject

B.

Output power

C.

Gain

D.

Dynamic range

Question # 36

Increasing which setting could enhance the visibility of acoustic shadowing posterior to a calcified object?

A.

Gain

B.

Output power

C.

Dynamic range

D.

Frequency

Question # 37

What is the primary reason lateral resolution varies at different depths?

A.

Beam width

B.

Pulse length

C.

Tissue texture

D.

Acoustic impedance

Question # 38

Which parameter is directly proportional to the Doppler shift frequency?

A.

Propagation speed

B.

Size of moving reflector

C.

Ultrasound beam intensity

D.

Velocity of the moving reflector

Question # 39

Which factor improves axial resolution?

A.

Shorter spatial pulse length

B.

Lower frequency transducer

C.

Narrower beamwidth

D.

Decreased compression

Question # 40

Which adjustment is needed to optimize the waveform below?

SPI question answer

A.

Lower baseline

B.

Decrease gain

C.

Increase wall filter

D.

Increase pulse repetition frequency

Question # 41

What is the primary determining factor of the fundamental frequency for pulsed wave transducers?

A.

Element thickness

B.

Crystal diameter

C.

Transducer type

D.

Propagation speed

Question # 42

What is ensemble length (packet size)?

A.

Length of pulses per scan line

B.

Number of pulses along a scan line

C.

Amplitude of pulses along the scan line

D.

Velocity of pulses along the scan line

Question # 43

Which change would lead to a reduction in frame rate?

A.

Increasing the number of focal zones

B.

Increasing the pulse repetition frequency (PRF)

C.

Decreasing the depth

D.

Decreasing the sector width

Question # 44

Which ultrasound adjustment allows for an increased frame rate in color flow Doppler?

A.

Using continuous wave Doppler

B.

Decreasing depth

C.

Using multiple focal zones

D.

Increasing sector scan width

Question # 45

What does changing the displayed depth control directly affect?

A.

Pulse repetition frequency

B.

Transducer transmit frequency

C.

Pulse duration

D.

Spatial pulse length

Question # 46

How is an ultrasound image affected if several adjacent crystals of a linear array transducer are damaged?

A.

Vertical dark zone directly below the damaged elements

B.

Erratic beam steering and focusing

C.

Horizontal zone of dropout

D.

Loss of entire image

Question # 47

What is the purpose of applying compression to the received signals?

A.

Decrease the frame rate

B.

Decrease the spatial pulse length

C.

Reduce the field of view

D.

Reduce the dynamic range

Question # 48

Which function is the purpose of the matching layer?

A.

Convert acoustic to electrical energy

B.

Allow sequential firing of elements

C.

Reduce ringing of the crystals

D.

Increase sound transmission

Question # 49

Which resolution capability is most affected by spatial pulse length?

A.

Elevational

B.

Temporal

C.

Lateral

D.

Axial

Question # 50

Which statement characterizes the primary difference between image A and image B?

SPI question answer

A.

Image A demonstrates a better axial resolution.

B.

Image A demonstrates a lower overall gain setting.

C.

Image A demonstrates a shallower field of view.

D.

Image A demonstrates a wider scale of contrast.

Question # 51

Which color Doppler artifact is visualized in this image?

SPI question answer

A.

Ghosting

B.

Aliasing

C.

Twinkle

D.

Bleed

Question # 52

Which adjustment will reduce the appearance of posterior shadowing artifact?

A.

Increasing spatial compounding

B.

Decreasing dynamic range

C.

Decreasing the number of focal zones

D.

Increasing persistence

Question # 53

Which color Doppler setting can be optimized to eliminate low-frequency Doppler shifts without having any effect on higher Doppler frequency shifts?

A.

Gain

B.

Scale

C.

Wall filter

D.

Persistence

Question # 54

What is effected by increasing the color scale?

A.

The Nyquist limit is increased

B.

More colors are displayed

C.

The color box width decreases

D.

The color priority decreases

Question # 55

Which process is used to fill in blank spaces between scan lines?

A.

Logarithmic compression

B.

Coded excitation

C.

Autocorrelation

D.

Interpolation

Question # 56

Which resolution is improved by focusing?

A.

Lateral

B.

Axial

C.

Temporal

D.

Contrast

SPI PDF

$33

$109.99

3 Months Free Update

  • Printable Format
  • Value of Money
  • 100% Pass Assurance
  • Verified Answers
  • Researched by Industry Experts
  • Based on Real Exams Scenarios
  • 100% Real Questions

SPI PDF + Testing Engine

$52.8

$175.99

3 Months Free Update

  • Exam Name: Sonography Principles and Instrumentation
  • Last Update: Dec 15, 2025
  • Questions and Answers: 187
  • Free Real Questions Demo
  • Recommended by Industry Experts
  • Best Economical Package
  • Immediate Access

SPI Engine

$39.6

$131.99

3 Months Free Update

  • Best Testing Engine
  • One Click installation
  • Recommended by Teachers
  • Easy to use
  • 3 Modes of Learning
  • State of Art Technology
  • 100% Real Questions included