New Year Special Sale - 70% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: spcl70

Practice Free DES-1721 Specialist - Implementation Engineer SC Series Exam Exam Questions Answers With Explanation

We at Crack4sure are committed to giving students who are preparing for the EMC DES-1721 Exam the most current and reliable questions . To help people study, we've made some of our Specialist - Implementation Engineer SC Series Exam exam materials available for free to everyone. You can take the Free DES-1721 Practice Test as many times as you want. The answers to the practice questions are given, and each answer is explained.

Question # 6

Refer to the exhibit.

DES-1721 question answer

The servers are zoned to best practices. The output of the switch is shown below:

DES-1721 question answer

Which is the Physical Zone of Fault Domain B?

A.

Zone_A

B.

Zone_C

C.

Zone_D

D.

Zone_B

Question # 7

You are implementing a front-end connection in Legacy Port Mode on an SC4020 in a SAN with two iSCSI switches. What is the minimum number of port(s), per switch, that can be used by each controller?

A.

One port on each Ethernet switch

B.

Two ports on each Ethernet switch

C.

Four ports on each Ethernet switch

D.

Eight ports on each Ethernet switch

Question # 8

When a SC is in a failover state what will occur in the surviving controller?

A.

Data and metadata will be available

B.

The read cache that is associated with the failed controller will be created

C.

The deduplication dictionary from the failed controller will load

D.

Deduplication will run

Question # 9

Which component of the Dell Storage Manager (DSM) Suite’s only purpose is to perform disaster recovery?

A.

Dell Storage Manager Remote Data Collector

B.

Dell Storage Manager Primary Data Collector

C.

Dell Storage Manager Server Agent

D.

Dell Storage Manager Client

Question # 10

You are installing an SC8000 array and the customer notices that each of the controllers only have 16 GB of memory. The customer wants to maximize this memory. What is the maximum RAM supported on a single SC8000 controller?

A.

32 GB

B.

64 GB

C.

128 GB

D.

256 GB

Question # 11

A customer notices a volume is using an above average amount of Tier 1 RAID 10 space. What can be done to force this data into a lower RAID set/Tier?

A.

Stop I/O to the volume

B.

Change the storage profile of the volume

C.

Take a manual snapshot

D.

Move data to a different volume

Question # 12

What is the maximum number of Fault Domains on a SCv3000 Storage Center using SAS front-end?

A.

1

B.

2

C.

3

D.

4

Question # 13

You have installed the Dell Storage Manager (DSM) Client first and then the Data Collector. When attempting to connect to the newly installed Data Collector, you receive an error message, saying: no connection could be established.

What could be the cause of this error?

A.

Firewall is blocking database connection of the Data Collector.

B.

Wrong login credentials have been entered into the DSM Client.

C.

Data Collector service may not have completely started.

D.

Incompatible version of DSM Client was installed.

Question # 14

While setting up replication, you see an option for “Replication Deduplication”. What is the function of this option?

A.

Provides the same function as Data Reduction, Deduplication

B.

Compresses and deduplicates data prior to replicating

C.

Replicates only the data that has changed in a page

D.

Replicates the entire page and deduplicates on the destination system

Question # 15

A customer is concerned they are over utilizing their 7K drives. Where can information about the real time I/O usage of individual drives be viewed?

A.

Hardware > Disks > [disk folder] > [disk number]

B.

Charting > Disks > [disk folder] IO Charts

C.

Charting > Disks > [disk folder] > [disk number]

D.

Hardware > Disks > [disk folder]

Question # 16

Where are Dell Storage Manager (DSM) automated reports stored for later access?

A.

DSM database

B.

DSM file system

C.

First created volume

D.

External document management system

Question # 17

You are implementing a front-end connection in Legacy Port Mode on an SC4020 in a SAN with two iSCSI switches. What is the minimum number of port(s), per switch, that can be used by the SC Series array?

A.

One port on each of the Ethernet switches

B.

Two ports on each of the Ethernet switches

C.

Four ports on each of the Ethernet switches

D.

Eight ports on each of the Ethernet switches

Question # 18

How much memory does the Dell Storage Manager (DSM) Virtual Appliance require to manage seven SC Series arrays?

A.

2 GB

B.

4 GB

C.

8 GB

D.

16 GB

Question # 19

How many SC400 enclosures can be supported by an SC7020 controller?

A.

8

B.

10

C.

12

D.

16

Question # 20

Refer to the Exhibit.

DES-1721 question answer

A customer has asked you to perform a port failover test to demonstrate system resiliency. What is needed to complete this task?

A.

Add more cables per switch

B.

Switch to Legacy Port Mode

C.

Add more switches per controller

D.

Switch to Virtual Port Mode

Question # 21

You are testing a new SC7020 storage array. You decided to deploy a temporary installation of Dell Storage Manager (DSM) Data Collector with an embedded database. What is the maximum number of days in which array information can be retained?

A.

15 days

B.

30 days

C.

60 days

D.

90 days

Question # 22

What is order of steps that the Storage Center will follow when it senses that the UPS has lost input power?

DES-1721 question answer

Question # 23

How many SC220 enclosures can be supported by an SC4020 storage array?

A.

7

B.

9

C.

14

D.

15

Question # 24

An administrator wants to configure an SC Series array to use Virtual Port Mode. What is a requirement to accomplish this task?

A.

NPIV must be disabled on Fibre Channel switches

B.

I/O Controller cards must use a single-ID firmware version

C.

Fibre Channel switches must use a switched fabric topology

D.

Activation license must be purchased and installed

Question # 25

For what is Application Protection Manager used?

A.

SQL databases

B.

Hyper-V machine resources

C.

VMware virtual machines

D.

Oracle databases

Question # 26

A customer wants to add an iSCSI path to a Microsoft Windows Server 2012 R1. The server has an existing Fibre Channel path to an SC7020 array for load balancing and high availability.

Which Windows MPIO policy should be configured to achieve the customer’s requirement?

A.

Fail Over Only

B.

Weighted Paths

C.

Round Robin with Subset

D.

Round Robin

Question # 27

In an SC Series environment, which Fibre Channel zoning method is more secure?

A.

WWN

B.

Single Initiator/Single Target

C.

Single Initiator/Multi-Target

D.

Port

Question # 28

During the initial installation of a new SC9000 Storage Center, which Dell Storage Manager (DSM) Client option should be selected?

A.

Configure this host to access a Storage Center

B.

Configure VMware vSphere to access a Storage Center

C.

Discover and Configure Uninitialized SCv2000 or SC7000 Series Storage Centers

D.

Login to a Storage Center or Data Collector

Question # 29

What information is required to configure an iSCSI initiator?

A.

Alias, Zone, Zone Config name

B.

Target IP Address, subnet, gateway

C.

VLAN tag, port speed, Multicast control setting

D.

MAC address, VLAN broadcast address

Question # 30

The storage profile of a volume has changed. What is the correct statement regarding the newly written pages of this volume?

A.

Move after 12 cycles of Data Progression

B.

Will follow the new storage profile immediately

C.

Move during the next Data Progression

D.

Move after creation of a view volume

Question # 31

How many SAS ports are used on each EMM of an SC460?

A.

1

B.

2

C.

3

D.

4

Question # 32

The SC configuration consists of a SC7020, two (2) FC switches and four (4) Servers with a dual port FC HBA. How many zones are required for the SC to run with virtual port mode enabled?

A.

2

B.

4

C.

6

D.

8

Question # 33

Assume a storage administrator is using the recommended storage profile. What describes the distribution of volume data residing in an SC series storage array that has 15K and 7K as the back-end?

A.

New and frequently accessed replay data in Tier 1 RAID 5Aged replay data and inaccessible data in Tier 3 RAID 6

B.

New data in Tier 1 RAID 10Frequently accessed replay data in Tier 1 RAID 5Aged replay data and inaccessible data in Tier 3 RAID 6

C.

New data in Tier 1 RAID 10Frequently accessed replay data in Tier 2 RAID 5Aged replay data and inaccessible data in Tier 3 RAID 6

D.

New and frequently accessed replay data in Tier 1 RAID 10Aged replay data and inaccessible data in Tier 3 RAID 6

Question # 34

You want to create a notification setting to help monitor how full the volumes are on an SC9000 system. In Dell Storage Manager (DSM), where would a schedule to only trigger these alerts during business hours be set up?

A.

“Edit Automated Report Settings”

B.

“Edit Data Collector Settings”

C.

“Threshold Alerts” Definition

D.

“Storage Center Summary” Report

Question # 35

To allow the Storage Center Update Utility (SCUU) to serve updates, which inbound TCP port should be opened on the Microsoft Windows firewall?

A.

443

B.

3033

C.

8443

D.

9005

Question # 36

When installing an SC Series array, the customer indicated that they want the controller configured to provide the maximum amount of storage space. You discover that the storage controller was shipped with twelve 900 GB drives and twelve 1.8 TB drives of the same type.

Which redundancy level can be selected to provide the maximum amount of storage?

A.

Put equal size drives in their own pagepool.Change the default redundancy level for the 1.8 TB drives.

B.

Put all drives in the same tier.Keep the default redundancy level for both the 900 GB and 1.8 TB drives.

C.

Put equal size drives in their own tier.Change the default redundancy level for the 900 GB drives.

D.

Put equal size drives in their own pagepool.Keep the default redundancy level for both the 900 GB and 1.8 TB drives.

Question # 37

You are trying to discover a brand new SCv3020 but the process if failing. DHCP is not available. What is the best solution for this issue?

A.

Enable MTU and flowcontrol on the switch

B.

Configure IPv4 address on the system running the DSM Client on the target subnet

C.

Set BMC IPs

D.

Configure IPv4 on DSM Client machine and enable IPv6 addressing

Question # 38

Based on the exhibit, a customer is using a Virtual Port Mode configuration. If the cable for Domain 1 on Controller 1 is disconnected during failover testing, will the SC Series array port failover work?

DES-1721 question answer

A.

No, the configuration contains only a single port per domain and will not provide port failover.

B.

Yes, the configuration will provide port failover as the system is configured for Virtual Port Mode.

C.

No, port failover only works in Legacy Port Mode.

D.

Yes, the configuration will provide port failover regardless of domains or mode.

Question # 39

Refer to the exhibits.

Which is the correct front end and cabling for an SC7020 with 2 port FC connectivity?

A)

DES-1721 question answer

B)

DES-1721 question answer

C)

DES-1721 question answer

D)

DES-1721 question answer

A.

Option A

B.

Option B

C.

Option C

D.

Option D

Question # 40

Which SC Series licenses are applied at the factory?

A.

SC4020 and SC7020

B.

SC7020 and SCv2000

C.

SC8000 and SC9000

D.

SCv2000 and SC8000

Question # 41

In an SC Series environment, which Fibre Channel zoning method is more flexible?

A.

Port

B.

Single Initiator/Multi-Target

C.

Single Initiator/Single Target

D.

WWN

Question # 42

An SC9000 controller was rebooted to test failover and is back online. Do the controllers need to be rebalanced?

A.

Yes; however, the other controller needs to be rebooted first

B.

No; this is done automatically as part of the reboot process in DSM

C.

No; they are automatically rebalanced on the SC9000

D.

Yes; this can be done from the Summary, Storage, or Hardware tab in DSM

Question # 43

What is the correct system hierarchy of SC Series array storage virtualization?

DES-1721 question answer

Question # 44

Which SC Series array feature allows all front-end ports to act as active data paths?

A.

Dual Fabric

B.

ALUA

C.

Virtual Port Mode

D.

Legacy Port Mode

DES-1721 PDF

$33

$109.99

3 Months Free Update

  • Printable Format
  • Value of Money
  • 100% Pass Assurance
  • Verified Answers
  • Researched by Industry Experts
  • Based on Real Exams Scenarios
  • 100% Real Questions

DES-1721 PDF + Testing Engine

$52.8

$175.99

3 Months Free Update

  • Exam Name: Specialist - Implementation Engineer SC Series Exam
  • Last Update: Dec 14, 2025
  • Questions and Answers: 147
  • Free Real Questions Demo
  • Recommended by Industry Experts
  • Best Economical Package
  • Immediate Access

DES-1721 Engine

$39.6

$131.99

3 Months Free Update

  • Best Testing Engine
  • One Click installation
  • Recommended by Teachers
  • Easy to use
  • 3 Modes of Learning
  • State of Art Technology
  • 100% Real Questions included