We at Crack4sure are committed to giving students who are preparing for the EMC DES-1721 Exam the most current and reliable questions . To help people study, we've made some of our Specialist - Implementation Engineer SC Series Exam exam materials available for free to everyone. You can take the Free DES-1721 Practice Test as many times as you want. The answers to the practice questions are given, and each answer is explained.
Refer to the exhibit.

The servers are zoned to best practices. The output of the switch is shown below:

Which is the Physical Zone of Fault Domain B?
You are implementing a front-end connection in Legacy Port Mode on an SC4020 in a SAN with two iSCSI switches. What is the minimum number of port(s), per switch, that can be used by each controller?
When a SC is in a failover state what will occur in the surviving controller?
Which component of the Dell Storage Manager (DSM) Suite’s only purpose is to perform disaster recovery?
You are installing an SC8000 array and the customer notices that each of the controllers only have 16 GB of memory. The customer wants to maximize this memory. What is the maximum RAM supported on a single SC8000 controller?
A customer notices a volume is using an above average amount of Tier 1 RAID 10 space. What can be done to force this data into a lower RAID set/Tier?
What is the maximum number of Fault Domains on a SCv3000 Storage Center using SAS front-end?
You have installed the Dell Storage Manager (DSM) Client first and then the Data Collector. When attempting to connect to the newly installed Data Collector, you receive an error message, saying: no connection could be established.
What could be the cause of this error?
While setting up replication, you see an option for “Replication Deduplication”. What is the function of this option?
A customer is concerned they are over utilizing their 7K drives. Where can information about the real time I/O usage of individual drives be viewed?
Where are Dell Storage Manager (DSM) automated reports stored for later access?
You are implementing a front-end connection in Legacy Port Mode on an SC4020 in a SAN with two iSCSI switches. What is the minimum number of port(s), per switch, that can be used by the SC Series array?
How much memory does the Dell Storage Manager (DSM) Virtual Appliance require to manage seven SC Series arrays?
How many SC400 enclosures can be supported by an SC7020 controller?
Refer to the Exhibit.

A customer has asked you to perform a port failover test to demonstrate system resiliency. What is needed to complete this task?
You are testing a new SC7020 storage array. You decided to deploy a temporary installation of Dell Storage Manager (DSM) Data Collector with an embedded database. What is the maximum number of days in which array information can be retained?
What is order of steps that the Storage Center will follow when it senses that the UPS has lost input power?

How many SC220 enclosures can be supported by an SC4020 storage array?
An administrator wants to configure an SC Series array to use Virtual Port Mode. What is a requirement to accomplish this task?
For what is Application Protection Manager used?
A customer wants to add an iSCSI path to a Microsoft Windows Server 2012 R1. The server has an existing Fibre Channel path to an SC7020 array for load balancing and high availability.
Which Windows MPIO policy should be configured to achieve the customer’s requirement?
In an SC Series environment, which Fibre Channel zoning method is more secure?
During the initial installation of a new SC9000 Storage Center, which Dell Storage Manager (DSM) Client option should be selected?
What information is required to configure an iSCSI initiator?
The storage profile of a volume has changed. What is the correct statement regarding the newly written pages of this volume?
How many SAS ports are used on each EMM of an SC460?
The SC configuration consists of a SC7020, two (2) FC switches and four (4) Servers with a dual port FC HBA. How many zones are required for the SC to run with virtual port mode enabled?
Assume a storage administrator is using the recommended storage profile. What describes the distribution of volume data residing in an SC series storage array that has 15K and 7K as the back-end?
You want to create a notification setting to help monitor how full the volumes are on an SC9000 system. In Dell Storage Manager (DSM), where would a schedule to only trigger these alerts during business hours be set up?
To allow the Storage Center Update Utility (SCUU) to serve updates, which inbound TCP port should be opened on the Microsoft Windows firewall?
When installing an SC Series array, the customer indicated that they want the controller configured to provide the maximum amount of storage space. You discover that the storage controller was shipped with twelve 900 GB drives and twelve 1.8 TB drives of the same type.
Which redundancy level can be selected to provide the maximum amount of storage?
You are trying to discover a brand new SCv3020 but the process if failing. DHCP is not available. What is the best solution for this issue?
Based on the exhibit, a customer is using a Virtual Port Mode configuration. If the cable for Domain 1 on Controller 1 is disconnected during failover testing, will the SC Series array port failover work?

Refer to the exhibits.
Which is the correct front end and cabling for an SC7020 with 2 port FC connectivity?
A)

B)

C)

D)

Which SC Series licenses are applied at the factory?
In an SC Series environment, which Fibre Channel zoning method is more flexible?
An SC9000 controller was rebooted to test failover and is back online. Do the controllers need to be rebalanced?
What is the correct system hierarchy of SC Series array storage virtualization?

Which SC Series array feature allows all front-end ports to act as active data paths?
3 Months Free Update
3 Months Free Update
3 Months Free Update