New Year Special Sale - 70% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: spcl70

Note! DES-6322 has been withdrawn. The new exam code is D-VXR-DY-23

Practice Free DES-6322 Specialist - Implementation Engineer-VxRail Exam Exam Questions Answers With Explanation

We at Crack4sure are committed to giving students who are preparing for the EMC DES-6322 Exam the most current and reliable questions . To help people study, we've made some of our Specialist - Implementation Engineer-VxRail Exam exam materials available for free to everyone. You can take the Free DES-6322 Practice Test as many times as you want. The answers to the practice questions are given, and each answer is explained.

Question # 6

What is a benefit of using the VxRail REST API?

A.

Remote upgrades of iDRAC related software only

B.

Automated security audit of VxRail clusters

C.

Automated log collection for VxRail clusters

D.

Polling for vSAN performance statistics

Question # 7

According to Dell best practices, which VxRail series can be deployed in either datacenters or remote locations?

A.

D Series

B.

V Series

C.

G Series

D.

E Series

Question # 8

What is a difference between vSAN Data-In-Transit Encryption and vSAN Data-At-Rest-Encryption?

A.

Data-In-Transit Encryption: Encrypts traffic between VMs and the VxRail nodes

Data-At-Rest Encryption: Encrypts traffic between VxRail nodes only

B.

Data-In-Transit Encryption: Does not require a Key Management Server

Data-At-Rest Encryption: Requires a Key Management Server

C.

Data-In-Transit Encryption: Key Management Server must reside on the vSAN cluster

Data-At-Rest Encryption: Key Management Server can reside on the vSAN cluster

D.

Data-In-Transit Encryption: Addresses fear of media theft

Data-At-Rest Encryption: Addresses fear of rogue administrators

Question # 9

A VxRail 7.0.100 environment is managed by the internal vCenter Server. The customer asks the implementation engineer to deploy a new VxRail cluster using the existing vCenter Server.

What should the response of the engineer?

A.

Not supported for internal vCenter Server

B.

Not supported on VxRail software 7.0.100

C.

Supported by neither the internal vCenter Server nor external vCenter Server

D.

Only supported on VxRail software 4.7.xxx

Question # 10

A company needs to enable vSphere GPU capabilities on their VxRail cluster. To do so, they need to purchase a specific entitlement.

What licensing satisfies this requirement?

A.

vSphere Enterprise Plus

B.

vSAN Enterprise Plus Edition

C.

vSAN Advanced Edition

D.

vSphere Standard

Question # 11

What is the maximum number of supported nodes in a VxRail Stretch Cluster?

A.

16

B.

30

C.

32

D.

64

Question # 12

For which typical activity would the Full data migration setting be used when placing a VxRail host into maintenance mode?

A.

Temporary maintenance

B.

Rebooting a single ESXi host

C.

Shutting down an entire cluster

D.

Permanently removing host from cluster

Question # 13

An implementation engineer is tasked with setting up RecoverPoint for VMs on a single G Series chassis. How many VMs are licensed to be protected on the cluster?

A.

5

B.

10

C.

15

D.

20

Question # 14

What is the correct CLI command to collect only the vCenter logs on VxRail Manager

A.

vc-support.sh –v

B.

generateFullBundle.py –v

C.

vc-support-bundle.sh –c

D.

generateLogBundle.py –c

Question # 15

A 2-node VxRail duster Is being deployed. Due to a preparation mistake, the host section fe missing. Use the VxRail simulator to fully deploy the cluster using the JSON file.

Node Names:

vcluster-esxO 15-vrack

vcluster-esxO 16-vrack

Starting IP

Address: 192.168.10.15

Rack Name: Virtual Rack

Rack Position: 15-16

Passwords: Passwordl23

!

ESXI Management

User: esxmgmt

When you have finished, continue to the next question.

DES-6322 question answer

DES-6322 question answer

DES-6322 question answer

DES-6322 question answer

DES-6322 question answer

Question # 16

Match each component of the VxRail HCI System Software to its description.

DES-6322 question answer

Question # 17

Which two files are used to automate VxRail deployment and validate the network configuration?

A.

Appliance JSON file

PEQ data file

B.

VxRail Configuration Portal

PEQ data file

C.

VxRail Test Plan

SPEQ

D.

Appliance JSON file

SPEQ

Question # 18

An implementation engineer is deploying a new VxRail cluster What should they confirm before installing the hardware?

A.

At least 24 in (61 cm) of clearance exists in front of and behind the cabinet

B.

Redundant power zones exist with adequate power cables

C.

Power distribution supports only the power rating of a single node

D.

Service laptop is on the same IP network as the iDRACs

Question # 19

A VxRail API request has been executed and the user account does not have vCenter privileges to perform the task What code is returned?

A.

200

B.

207

C.

403

D.

500

Question # 20

What is a supported witness configuration for a 3+3+1 VxRail Stretched Cluster?

A.

vSAN Witness appliance with customer provided license

B.

Physical ESXi host with included cluster license

C.

Physical ESXi host with multiple VxRail clusters as witness

D.

vSAN Witness appliance or a physical ESXi host

Question # 21

How should an administrator manually validate the DNS readiness of a customer network?

A.

Run a traceroute to the DNS server

B.

Generate a Network PEQ

C.

Ping the default gateway of the management VLAN

D.

Run nslookup on server FQDN and IP

Question # 22

Which command is used to restart the Loudmouth process on an ESXi node?

A.

/usr/IibAmiware/loudmouth/bin/loudmouthd restart

B.

systemcti restart loudmouth

C.

/etc/int.d/loudmouth restart

D.

systemcti restart vmware-loudmouth

Question # 23

What is a consideration when adding nodes to a VxRail G Series chassis?

A.

G560 and G410 nodes are permitted in the same chassis

B.

In a full G Series chassis, all nodes must have 10GbE ports

C.

Hybrid and All-Flash nodes are permitted, if in different chassis

D.

All nodes in a G Series chassis must be identical

Question # 24

An implementation engineer is performing a precheck on a VxRail cluster before expansion. During validation, they find out that the host is not compatible.

Use the VxRail simulator to describe why the host is Incompatible.

Note: It is necessary to close (x) the simulator window before you can select a response to this question.

DES-6322 question answer

DES-6322 question answer

DES-6322 question answer

DES-6322 question answer

DES-6322 question answer

DES-6322 question answer

A.

bmc and bios are running older versions

B.

Insufficient number of vSphere licenses

C.

Firmware of ESXi host needs to be updated

D.

Invalid vCenter 5erver license

Question # 25

What is a consideration when expanding a VxRail cluster? (Choose two.)

A.

Mixing of All-Flash and all-NVMe nodes in a cluster is not allowed

B.

Expanding a cluster to 64 nodes requires a 25 GbE network

C.

G Series clusters can be expanded only with G Series nodes

D.

1 GbE must be hybrid and single processor node type

Question # 26

What is the minimum number of VxRail nodes required for a vSAN storage policy with RAID-5 (Erasure Coding)?

A.

3

B.

4

C.

5

D.

6

Question # 27

After implementation, the implementation engineer observes errors from both VxRail Manager and vCenter Server. Dell EMC support has requested a log bundle containing only the required log files. Using the simulator, create and download a log bundle for Dell EMC support.

When you have finished, continue to the next question.

DES-6322 question answer

DES-6322 question answer

DES-6322 question answer

DES-6322 question answer

DES-6322 question answer

DES-6322 question answer

Question # 28

A systems engineer needs to ensure that the VxRail system is healthy and any issues found are addressed prior to starting an upgrade process. Where in the vSphere Client can they review alarms and overall vSAN health?

A.

Triggered Alarms > Issues and Alarms > All issues

Triggered Alarams > vSAN > Skyline Health

B.

Monitor > All Issues > Issues and Alarms

Monitor > vSAN > Health

C.

Triggered Alarms > All Issues > Issues and Alarms

Triggered Alarms > vSAN > Health

D.

Monitor > Issues and Alarms > All issues

Monitor > vSAN > Skyline Health

Question # 29

Match each IDRAC Maintenance page tab to its description.

DES-6322 question answer

Question # 30

What is a characteristic of the VxRail S Series node?

A.

Form factor of 2U4N

B.

Large form factor drives

C.

Dense Flash disks

D.

Form factor of 1U1N

Question # 31

What is a consideration when performing a VxRail software upgrade from version 4.7.xxx to version 7.0.xxx?

A.

External vCenter server must be upgraded after the VxRail is upgraded

B.

vCenter Server requires a temporary IP address on a different subnet before the upgrade

C.

Secure boot must be enabled on the ESXi hosts for a successful upgrade

D.

VxRail Manager VM must be changed to the default name to avoid an upgrade failure