Refer to the exhibit.
A customer is moving some VMAX devices under a VPLEX Local and is using PowerPath as multipath software. What is the preferred PowerPath load balancing policy assigned to VPLEX volumes?
Which type of volume has complete synchronized copies of data (mirrors) in more than one cluster?
Refer to the exhibit.
After 6 months of operation, you are monitoring the health of the VPLEX system from the Unisphere Manager for VPLEX.
What is the most likely reason for a state change of the VPLEX Witness?
You have attempted to upgrade a VPLEX system to the latest Geosynchrony code. During the upgrade, an error appeared and caused the upgrade to fail.
Which file should you review to gather more information about the failure?
An EMC customer wants to add a mirror to a VPLEX Local RAID 0 device. Which RAID type is created after the device attach-mirror command is issued?
A new VPLEX cluster has been configured. However, you are unable to register any host initiators. After verifying that the host has been properly zoned to the VPLEX cluster, you still cannot register them. What is a possible cause?
A customer has a VPLEX Metro configuration across two data centers 200 km apart. During an overnight backup, the WAN-COM link between the two data centers fails.
Which volume allows for future incremental re-synchronization with the remote mirror once the link is restored?
What is the maximum cache of a single engine in a medium VPLEX VS2 cluster?
A customer has a VPLEX Metro installed. They asked you to recommend a method to non-disruptively move Virtual Volumes from a storage array at Cluster 1 to a storage array at Cluster 2. What would you recommend?
A customer has purchased a dual engine VPLEX Metro cluster. During installation, there are not enough free SAN ports to connect all WAN-COM ports to the SAN. What is the recommended approach?
Refer to the exhibit.
The customer deleted ext_2 on a 20 GB LUN in order to make an extent of 10 GB. Why is the customer unable to create a 10 GB extent?
A customer has ordered a new VPLEX, and you are on site doing the initial installation. When creating metadata volumes for the VPLEX Local configuration, the customer asks you how much total storage is needed for the VPLEX metadata. According to EMC best practices, what is the total minimum storage needed for this configuration?
In Unisphere for VPLEX, which storage array does not require a mapping file when claiming storage volumes?
You need to claim storage that is presented to VPLEX from a VNX. What is required in order to create the mapping file needed by the VPLEX Claim Storage Wizard?
What is the recommendation when executing collect-diagnostics command on a VPLEX Metro/GEO?
You are preparing a site for a large Metro VPLEX cluster. The storage administrator wants to prepare the storage network configuration and needs to ensure easy troubleshooting of storage path faults.
How many WAN-COM zones will need to be created?
What should be the maximum latency between a VPLEX Management Server and the Cluster Witness?
Refer to the exhibit.
After a power disruption of 20 seconds in a VPLEX environment, the output of the "vault status" command shows no vaulting processes.
Why did this occur?
What is the role of the port with the WWN 5000144270061010 on a VS2 engine?
Following EMC best practices, what information is required to register a VPLEX on an ESRS portal?
What is an EMC best practice for fault tolerance when zoning a VPLEX Metro together over Fibre Channel for successful communication between the sites?