Labour Day Special - 65% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: c4sdisc65

E20-260 PDF

$38.5

$109.99

3 Months Free Update

  • Printable Format
  • Value of Money
  • 100% Pass Assurance
  • Verified Answers
  • Researched by Industry Experts
  • Based on Real Exams Scenarios
  • 100% Real Questions

E20-260 PDF + Testing Engine

$61.6

$175.99

3 Months Free Update

  • Exam Name: VPLEX Specialist Exam for Implementation Engineers
  • Last Update: May 1, 2024
  • Questions and Answers: 210
  • Free Real Questions Demo
  • Recommended by Industry Experts
  • Best Economical Package
  • Immediate Access

E20-260 Engine

$46.2

$131.99

3 Months Free Update

  • Best Testing Engine
  • One Click installation
  • Recommended by Teachers
  • Easy to use
  • 3 Modes of Learning
  • State of Art Technology
  • 100% Real Questions included

E20-260 Practice Exam Questions with Answers VPLEX Specialist Exam for Implementation Engineers Certification

Question # 6

Refer to the exhibit.

E20-260 question answer

A customer is moving some VMAX devices under a VPLEX Local and is using PowerPath as multipath software. What is the preferred PowerPath load balancing policy assigned to VPLEX volumes?

A.

Fixed

B.

Adaptive

C.

Round Robin

D.

SymOpt

Full Access
Question # 7

Refer to the exhibit:

E20-260 question answer

Which two modules are used for back-end connectivity?

A.

A and E

B.

D and E

C.

B and F

D.

C and F

Full Access
Question # 8

Which type of volume has complete synchronized copies of data (mirrors) in more than one cluster?

A.

Distributed Device

B.

Extent

C.

Device

D.

Virtual Volume

Full Access
Question # 9

Refer to the exhibit.

E20-260 question answer

After 6 months of operation, you are monitoring the health of the VPLEX system from the Unisphere Manager for VPLEX.

What is the most likely reason for a state change of the VPLEX Witness?

A.

TheESXi host was rebooted.

B.

The WAN switch ports failed.

C.

The Management Server was restarted.

D.

TheMetaVolume was restored.

Full Access
Question # 10

You have attempted to upgrade a VPLEX system to the latest Geosynchrony code. During the upgrade, an error appeared and caused the upgrade to fail.

Which file should you review to gather more information about the failure?

A.

firmware.log_

B.

session.log

C.

VPlexconfiguration-session.txt

D.

ndu-pre-check-stderr.txt

Full Access
Question # 11

An EMC customer wants to add a mirror to a VPLEX Local RAID 0 device. Which RAID type is created after the device attach-mirror command is issued?

A.

RAID 1

B.

RAID 0

C.

RAID S

D.

RAID C

Full Access
Question # 12

A new VPLEX cluster has been configured. However, you are unable to register any host initiators. After verifying that the host has been properly zoned to the VPLEX cluster, you still cannot register them. What is a possible cause?

A.

Front end ports have not been enabled.

B.

Back-end ports have not been enabled.

C.

Back-end arrays have not presented any LUNs.

D.

Storage View for host has not been created.

Full Access
Question # 13

A customer has a VPLEX Metro configuration across two data centers 200 km apart. During an overnight backup, the WAN-COM link between the two data centers fails.

Which volume allows for future incremental re-synchronization with the remote mirror once the link is restored?

A.

Logging Volume

B.

Storage Volume

C.

Metadata Volume

D.

Virtual Volume

Full Access
Question # 14

What is the maximum cache of a single engine in a medium VPLEX VS2 cluster?

A.

72 GB

B.

36 GB

C.

144 GB

D.

78 GB

Full Access
Question # 15

What mobility operation must be performed to defragment storage volumes?

A.

Device Mobility

B.

Data Mobility

C.

Extent Mobility

D.

Virtual Volume Mobility

Full Access
Question # 16

A customer has a VPLEX Metro installed. They asked you to recommend a method to non-disruptively move Virtual Volumes from a storage array at Cluster 1 to a storage array at Cluster 2. What would you recommend?

A.

Use the Device Mobility feature of VPLEX.

B.

Use the Extent Mobility feature of VPLEX.

C.

Change the RAID protection to RAID 0

D.

Use array-based features to copy the storage volume, then rediscover the array.

Full Access
Question # 17

A customer has purchased a dual engine VPLEX Metro cluster. During installation, there are not enough free SAN ports to connect all WAN-COM ports to the SAN. What is the recommended approach?

A.

The customer must provide additional SAN ports or acquire additional SAN ports to connect all WAN-COM ports of both VPLEX engines to the SAN.

B.

The customer must connect the WAN-COM ports of the first engine only and disable the second engine from the VPLEX CLI.

C.

It is sufficient to connect the WAN-COM ports of either engine 1 or 2 because redundancy is provided by leveraging two separate SAN fabrics.

D.

The customer must connect the WAN-COM ports of the first engine only and disable the second engine from the Unisphere for VPLEX GUI.

Full Access
Question # 18

What are key benefits of storage virtualization with VPLEX?

A.

Ease of consolidations; device mobility; simplifying management; provisioning of multiple arrays.

B.

Consolidations; point-in-time backups; simplifying management; third-party array support.

C.

Device performance; point-in-time backups; third party array support; device mobility

D.

Synchronous SAN extension across long distances; device mobility; and third-party array support

Full Access
Question # 19

When should front-end ports be enabled during a VPLEX installation?

A.

After creating the meta-volumes and backup

B.

Before creating the meta-volumes and backup

C.

Before launching the VPLEX EZ-Setup Wizard

D.

After exposing storage to the hosts

Full Access
Question # 20

Where is the wwn-seed physically located on VS2 engines?

A.

On the back of the engine on the bottom of the chassis

B.

On the front of the management server

C.

On the front of the director

D.

On the front of the director bezel cover

Full Access
Question # 21

Refer to the exhibit.

E20-260 question answer

The customer deleted ext_2 on a 20 GB LUN in order to make an extent of 10 GB. Why is the customer unable to create a 10 GB extent?

A.

Storage array must be re-discovered.

B.

ext_2 cannot be deleted.

C.

Chunks of the storage need to be contiguous.

D.

The defrag property is set to false.

Full Access
Question # 22

A customer has ordered a new VPLEX, and you are on site doing the initial installation. When creating metadata volumes for the VPLEX Local configuration, the customer asks you how much total storage is needed for the VPLEX metadata. According to EMC best practices, what is the total minimum storage needed for this configuration?

A.

10 GB

B.

312 GB

C.

156 GB

D.

234 GB

Full Access
Question # 23

In Unisphere for VPLEX, which storage array does not require a mapping file when claiming storage volumes?

A.

VNX

B.

CLARiiON

C.

Celerra

D.

Symmetrix

Full Access
Question # 24

You need to claim storage that is presented to VPLEX from a VNX. What is required in order to create the mapping file needed by the VPLEX Claim Storage Wizard?

A.

A host with solutions enabler installed and zoned to SPA and SPB

B.

The user name, password and management address of the VNX

C.

A host with WinSCP installed, with an IP connection to the VPLEX Management Server

D.

The username and password of the VPLEX Management Server

Full Access
Question # 25

What is the recommendation when executing collect-diagnostics command on a VPLEX Metro/GEO?

A.

Do not run simultaneously on both Management servers

B.

Always use the --local-only option

C.

Always use the --noextended option

D.

Always use the --minimum option

Full Access
Question # 26

You are preparing a site for a large Metro VPLEX cluster. The storage administrator wants to prepare the storage network configuration and needs to ensure easy troubleshooting of storage path faults.

How many WAN-COM zones will need to be created?

A.

24

B.

16

C.

8

D.

32

Full Access
Question # 27

What should be the maximum latency between a VPLEX Management Server and the Cluster Witness?

A.

1 sec

B.

50 ms

C.

5 ms

D.

1 ms

Full Access
Question # 28

Refer to the exhibit.

E20-260 question answer

After a power disruption of 20 seconds in a VPLEX environment, the output of the "vault status" command shows no vaulting processes.

Why did this occur?

A.

The cache vaulting did not exceed the timer period.

B.

It is the expected output, because the command "vault status" doesn't show information on cache process at all.

C.

Cache vaulting process has already completed.

D.

Cache vaulting process is still running in background and it is not shown until completed.

Full Access
Question # 29

What is the role of the port with the WWN 5000144270061010 on a VS2 engine?

A.

Back-end

B.

Front-end

C.

Local-COM

D.

WAN-COM

Full Access
Question # 30

Following EMC best practices, what information is required to register a VPLEX on an ESRS portal?

A.

Site ID; cluster TLA serial number; Management server eth3 IP address

B.

License ID; engine serial number; Management server eth3 IP address

C.

Site ID; engine serial number; Management server eth3 IP address

D.

Site ID; cluster TLA serial number; Witness IP address

Full Access
Question # 31

What is an EMC best practice for fault tolerance when zoning a VPLEX Metro together over Fibre Channel for successful communication between the sites?

A.

Zone each WAN-COM port to all WAN-COM ports in the other fabric.

B.

Zone all WAN-COM ports to each other in both SAN fabrics within a single zone.

C.

Zone each WAN-COM port to all WAN-COM ports in the other fabric.

Zone one Local-COM port to all WAN-COM ports in the other fabric for VPLEX Witness.

D.

Zone all WAN-COM ports to each other in both SAN fabrics within a single zone.

Zone one Local-COM port to all WAN-COM ports in the other fabric for VPLEX Witness.

Full Access