We at Crack4sure are committed to giving students who are preparing for the EMC E20-526 Exam the most current and reliable questions . To help people study, we've made some of our XtremIO Solutions and Design Specialist Exam for Technology Architects exam materials available for free to everyone. You can take the Free E20-526 Practice Test as many times as you want. The answers to the practice questions are given, and each answer is explained.

Question # 6

A Linux administrator is attaching a new RHEL server to their XtremIO storage array. Which configuration setting should be changed?

A.

Enable Logical Volume Manager

B.

Modify the file system block size

C.

Disable HBA Queue Depth

D.

Disable I/O elevators

Question # 7

How should a storage administrator navigate to different XtremIO clusters from the XMS GUI if the administrator has more than one cluster managed by the same XMS?

A.

Click the Cluster Name on the Menu bar near the top of the screen

B.

Click the Inventory List button on the Menu bar

C.

Click the Administration tab and locate the Cluster Name

D.

Click the Cluster Name on the Status bar at the bottom of the screen

Question # 8

A customer has a workload with the following attributes:

  • Generates 250,000 IOPs
  • 100 TB in logical capacity
  • Read/Write ratio of 1:1
  • Random workload with 8 kB I/O size
  • Deduplication ratio of 2:1
  • Compression ratio of 2:1

Which XtremIO solution should be recommended to the customer?

A.

1×40 TB X-Brick

B.

2×10 TB X-Brick

C.

3×20 TB X-Brick

D.

4×10 TB X-Brick

Question # 9

Based on XtremIO best practice, which byte sector size should be used for volumes hosting Oracle database files?

A.

256

B.

512

C.

1024

D.

4096

Question # 10

A customer is considering migrating their existing non-EMC storage arrays to an XtremIO array. The current environment consists of 350 servers running VMware ESXi 5.5 with 5000 virtual machines. The customer has various tools in place to monitor performance and collect statistics. On average, their service time is 32 ms and utilization is at 75%. In the past, the customer has had performance issues.

Based on Little’s Law, what is the calculated response time on the existing environment?

A.

128 ms

B.

192 ms

C.

256 ms

D.

332 ms

Question # 11

You need to design an Oracle solution for a customer. Which XtremIO best practices should be used in Oracle environments?

A.

Use a 512 byte LUN sector size for databases. Use Eager Zeroed Thick formatting for ESXi

B.

Use a 4 kB LUN sector size for databases. Use Lazy Zeroed Thick formatting for ESXi

C.

Align data on 4 kB boundaries. Use Thin formatting on ESXi

D.

Align data on 4 kB boundaries. Use Lazy Zeroed Thick formatting on ESXi

Question # 12

A customer has a large ESX server environment they are considering deploying to XtremIO for a VDI implementation. To determine a baseline of the environment, you are proceeding with documenting each server’s CPU, NIC, and disk utilization statistics. The customer has provided you with direct CLI access to the servers to conduct this assessment.

Which utility should be used to monitor these performance parameters?

A.

esxtop

B.

resxtop

C.

top

D.

iostat

Question # 13

An administrator receives an error on an XtremIO array while performing snapshot refreshes to a production volume. What is a potential cause for this issue?

A.

Refresh of the production volume is not supported

B.

Volume was not unmapped on the XtremIO cluster

C.

Only snapshot-to-snapshot refresh is supported

D.

Volume was not unmounted on the host

Question # 14

A customer is considering a six brick dispersed cluster using 3×40U racks. The customer wants advice on racking the InfiniBand switches.

  • Rack 1 (left) contains X-Bricks 1 and 2
  • Rack 2 (middle) contains X-Bricks 3 and 4
  • Rack 3 (right) contains X-Bricks 5 and 6

Which recommendation should be provided?

A.

Install the InfiniBand switches in Rack 1 with a 1U placeholder between the switches.

B.

Install an InfiniBand switch in Racks 1 and 3 with a 1U placeholder between the X-Bricks.

C.

Install the InfiniBand switches in Rack 2 with a 1U placeholder between the switches.

D.

Install the InfiniBand switches in Rack 3 with a 2U placeholder between the switches

Question # 15

When using XtremIO storage with Solaris (SPARC), what is the EMC recommended I/O size that will deliver sequential I/O more efficiently to XtremIO?

A.

1 MB

B.

2 MB

C.

4 MB

D.

8 MB

Question # 16

A customer currently uses XtremIO native remote replication with four RPAs and a 1 GB WAN link to asynchronously protect all production data. Management has decided that all data stored on the XtremIO must now be protected at the disaster recovery site by synchronous replication.

How can this be achieved?

A.

Set the Link Policy to Synchronous, Dynamic by throughput

B.

Purchase four additional RPAs.

C.

Set the Link Policy to Synchronous, Dynamic by latency

D.

Use a VPLEX splitter

Question # 17

Which level of granularity does XtremIO deduplication run?

A.

Variable 8 kB

B.

Variable 32 kB

C.

Fixed 8 kB

D.

Fixed 32 kB

Question # 18

A customer has recently deployed an XtremIO 20 TB two X-Brick cluster to run an existing instance of Oracle RAC previously leveraging VNX for back-end storage. The application environment uses a block size of 1 MB. Multiple tables are in use with the PARALLEL_DEGREE_POLICY variable set to AUTO.

The customer wants your help with tuning the DB_FILE_MULTIBLOCK_READ_COUNT parameter for best performance with XtremIO. Which values should be recommended for tuning the DB_FILE_MULTIBLOCK_READ_COUNT parameter in the Oracle RAC environment?

A.

8 or 16

B.

24 or 32

C.

64 or 128

D.

256 or 512

Question # 19

A customer is interested in purchasing XtremIO for their mission critical database applications that require the lowest possible response times. They have two data centers in which they want to introduce All-Flash arrays. However, they need a way to maintain true active/active access to all databases and application LUNs across both sites.

What is the recommended solution to address the requirements?

A.

ViPR Controller with XtremIO

B.

RecoverPoint with XtremIO

C.

VPLEX Metro with XtremIO

D.

ViPR SRM with XtremIO

Question # 20

Which multipathing software is supported by XtremIO?

A.

PowerPath/VE and NMP on ESXi hosts

B.

MPIO on non-clustered Microsoft Windows hosts only

C.

PowerPath/VE on Microsoft Windows VMs hosted by ESXi

D.

Native MPIO on IBM AIX clusters

E20-526 PDF

$33

$109.99

3 Months Free Update

  • Printable Format
  • Value of Money
  • 100% Pass Assurance
  • Verified Answers
  • Researched by Industry Experts
  • Based on Real Exams Scenarios
  • 100% Real Questions

E20-526 PDF + Testing Engine

$52.8

$175.99

3 Months Free Update

  • Exam Name: XtremIO Solutions and Design Specialist Exam for Technology Architects
  • Last Update: Dec 15, 2025
  • Questions and Answers: 67
  • Free Real Questions Demo
  • Recommended by Industry Experts
  • Best Economical Package
  • Immediate Access

E20-526 Engine

$39.6

$131.99

3 Months Free Update

  • Best Testing Engine
  • One Click installation
  • Recommended by Teachers
  • Easy to use
  • 3 Modes of Learning
  • State of Art Technology
  • 100% Real Questions included