We at Crack4sure are committed to giving students who are preparing for the Exin CDCP Exam the most current and reliable questions . To help people study, we've made some of our Certified Data Centre Professional (CDCP) exam materials available for free to everyone. You can take the Free CDCP Practice Test as many times as you want. The answers to the practice questions are given, and each answer is explained.

Question # 6

Which one of the following is an Objective of Data Center Fire Protection?

A.

Information

B.

Representation

C.

Depression

D.

Suppression

Question # 7

What is the minimum clearance space required below water sprinkler heads and nozzles of gas-based fire suppression systems?

A.

46 cm / 18 inches

B.

64 cm / 25 inches

C.

60 cm / 24 inches

D.

120 cm / 47 inches

Question # 8

What is the purpose of a service corridor?

A.

To create a secure and conditioned environment where media can be stored in a controlled manner.

B.

It is a generic name for pathways leading to other rooms that contains facility supporting equipment like the UPS room, battery room, generator room etc.

C.

It provides a safe, vented and secure area where standby generators can operate safely.

D.

It provides a secure area where supporting facilities can be serviced and monitored on a 24x7 basis without disturbing the computer room.

Question # 9

When designing a data centre with a raised-floor setup, where should the air conditioners be placed?

A.

Perpendicular to the hot aisle

B.

Perpendicular to the cold aisle

C.

Close to the entrance door to create an air curtain to avoid hot comes into the computer room

D.

Perpendicular to the side of the rack

Question # 10

Looking from within the Computer room, what should the door-swing (opening) direction be?

A.

Outwards, code permitted

B.

Instead of swinging doors, sliding doors are preferred

C.

Depends on the type of Computer room

D.

Inwards, code permitted

Question # 11

What is the main difference between an Environmental Monitoring System (EMS) and a Building Management System (BMS)?

A.

An EMS provides local alarms. A BMS provides both local and remote alarms.

B.

A BMS is only able to monitor dry contacts (on/off). An EMS can also monitor analog values.

C.

A BMS only operates as a stand-alone system. An EMS can be configured as a redundant system.

D.

An EMS monitors only. A BMS monitors and controls.

Question # 12

Which type of Humidifier rapidly vibrates waster to create a fog or mist?

A.

Infrared Humidifier

B.

Water Canister Humidifier

C.

Steam Canister Humidifier

D.

Ultrasonic Humidifier

Question # 13

Sprinkler heads used in computer rooms activate at what temperature?

A.

57 °C (135 °F)

B.

27 °C (81 °F)

C.

70 C (158 °F)

D.

Only on direct contact with a flame

Question # 14

An optical fiber cable comes with the specifications 50/125 um.

What do the numbers represent?

A.

The first number represents the distance for a 10 Gb/s connection; the second number represents the distance for a 1 Gb/s connection.

B.

The first number represents the diameter of the core; the second number represents the diameter of the cladding in microns.

C.

The first number represents the diameter of the core; the second number represents the actual diameter cable including the buffer and jacket.

D.

The first number represents the required distance to single-phase power cabling; the second number represents the required distance to three-phase cabling.

Question # 15

What is a requirement of an FM200 (HFC-227) installation?

A.

It is a high-pressure gas; therefore nozzles must be mounted with two brackets.

B.

Drainage system under the raised floor.

C.

Install the gas containers (tanks) close to the data centre.

D.

Install pre-action sprinklers in the same room as the FM200.

Question # 16

Which formula can provide a simple 'cost of downtime per hour" without taking seasonality and other factors into account?

A.

Revenue/52

B.

Revenue/1024

C.

Revenue/365

D.

Revenue/8760

Question # 17

The termination of the ability of a product to perform its required function can be defined as.

A.

Failure

B.

Termination

C.

Hindrance

D.

Obstacle

Question # 18

Which one of the following is an Audible Signaling and Notification Device?

A.

Sirens

B.

Strobes

C.

Alarms

D.

Clocks

Question # 19

Which one of the following is used in Measuring Business Value?

A.

Regeneration Cost

B.

Scalability

C.

Reliability

D.

Upfront Cost

Question # 20

The three elements of the fire triangle are,and. (Choose three.)

A.

Oxygen

B.

Earth

C.

Heat

D.

Water

E.

Fuel

Question # 21

What is the main risk for a data centre when the water supply fails?

A.

Failure to the water supply could result in IT failure and/or denial of access to operate.

B.

Failure to the water supply could result in DX cooling systems to fail.

C.

Failure to the water supply could cause issues for the cooling of back-up generators.

D.

Failure to the water supply could result in sudden changes of the relative humidity in the Computer room.

Question # 22

What type of heal does ICT equipment generate?

A.

Latent heal

B.

Sensible heaT

C.

Both latent and sensible heat

D.

Radiant heat

Question # 23

What is the most cost-effective way to avoid EMF issues within the Computer room?

A.

Create a distance between the EMF source and the ICT equipment / copper network cabling

B.

Install TUVapp'oved shielding material

C.

Reducing the voltage in the computer room

D.

Reducing the temperature in computer room to 18° C / 64= Fahrenheit

Question # 24

How many monitoring points should be used in Temperature Measurement?

A.

1

B.

2

C.

3

D.

4

Question # 25

Which Class of Fires involves cooking appliances?

A.

Class A

B.

Class B

C.

Class C

D.

Class K

Question # 26

What is the effect of a high relative humidity in the data centre?

A.

There is a risk of electrostatic discharge.

B.

In a data centre environment relative humidity is not important, only temperature matters.

C.

There is a risk of not properly functioning of the smoke detectors.

D.

There is a risk of corrosion.

CDCP PDF

$33

$109.99

3 Months Free Update

  • Printable Format
  • Value of Money
  • 100% Pass Assurance
  • Verified Answers
  • Researched by Industry Experts
  • Based on Real Exams Scenarios
  • 100% Real Questions

CDCP PDF + Testing Engine

$52.8

$175.99

3 Months Free Update

  • Exam Name: Certified Data Centre Professional (CDCP)
  • Last Update: Nov 30, 2025
  • Questions and Answers: 88
  • Free Real Questions Demo
  • Recommended by Industry Experts
  • Best Economical Package
  • Immediate Access

CDCP Engine

$39.6

$131.99

3 Months Free Update

  • Best Testing Engine
  • One Click installation
  • Recommended by Teachers
  • Easy to use
  • 3 Modes of Learning
  • State of Art Technology
  • 100% Real Questions included