We at Crack4sure are committed to giving students who are preparing for the Huawei H13-624_V5.5 Exam the most current and reliable questions . To help people study, we've made some of our HCIP-Storage V5.5 exam materials available for free to everyone. You can take the Free H13-624_V5.5 Practice Test as many times as you want. The answers to the practice questions are given, and each answer is explained.
An Internet customer has deployed a remote replication environment based on multiple flash storage devices. During actual service running, the customer discovers that there are multiple running statuses for a remote replication pair. Which of the following statements is true about the running status of a pair?
An industry customer has purchased several Huawei flash storage devices for service deployment. To improve service data reliability, an engineer configures the HyperReplication feature on the storage devices. If the engineer wants to modify the properties of a remote replication pair, which of the following commands cannot be used? (Choose all that apply)
During routine O & M, an engineer finds that the system time of multiple Huawei flash storage devices Is Incorrect, and needs to correct the system time. Which of the following Is not a possible impact of changing the system time?
uses Huawei's optimized FlexFC algorithm. This algorithm allows the system to tolerate simultaneous failures of three disks, greatly shortening the reconstruction time and
effectively addressing data protection challenges in the large capacity disk era.
A government customer has purchased two Huawei flash storage devices and deployed them in different data centers for running remote replication services. When a primary/secondary switchover is performed for the remote replication pair, the primary and secondary sites record the data changes. When the secondary site becomes the primary site following the primary/secondary switchover, all data will be synchronized between the primary and secondary sites.
In Huawei flash storage. If you want to apply the HyperCDP feature to a LUN, you are advised to reserve 5% to 10% of the LUN capacity in the storage pool to which the I UN belongs for storing HyperCDP object data, and configure a protection capacity threshold for the storage pool to stop creating HyperCDP objects or even automatically delete HyperCDP objects when the storage pool capacity is insufficient.
In a flash storage system, the ports of the cascading interface module or onboard cascading ports on the controller enclosure can only connect to port PI on the disk enclosure.
Assume a financial customer purchased multiple Huawei OceanStor Dorado 18000 storage devices to carry service data. A Fibre Channel link exception occurred in the storage environment. Which of the following are possible causes for this exception?
A school customer has purchased two Huawei flash storage devices and deployed them in different equipment rooms. To ensure data and service reliability, an engineer deploys the HyperReplication (remote replication) feature on the storage devices. After a fault recovery, the engineer needs to manually synchronize data to restore the pair relationship between the primary and secondary LUNs. What is the current running status of the remote replication pair?
A government customer has purchased several Huawei OceanStor Pacific series storage devices. An engineer wants to install the distributed parallel client (DPC) on the storage devices. The operations before DPC installation have been completed. Now, the engineer needs to add DPC nodes. Which of the following statements are true about adding nodes?
When learning the SmartVirtualization feature of Huawei flash storage, a new employee is not familiar with eDevLUNs and external LUNs. Which of the following statements are true about the eDevLUNs and external LUNs?
An engineer configures the HyperClone feature on a Huawei OceanStor Dorado 3000 storage system. The secondary LUN is configured with 20 GB and the primary LUN with 10 GB. In this case, reverse synchronization can be implemented. During the reverse synchronization, the capacity of the primary LUN cannot be expanded.
When delivering Huawei all-flash projects, Huawei engineers introduced the HyperCDP feature of flash storage to customers. Which of the following statements are true about this feature?
A faulty storage hardware module needs to be replaced. Which of the following components can be replaced online?
In Huawei all flash storage, the_____feature can automatically store data in different locations based on specified rules for intelligent data management.
Huawel OceanStor Pacific series products provide object storage capabilities and support cross-site disaster recovery (DR). Which of the following statements about object storage cross-site DR is false?
Assume a government office purchases a Huawel OceanStor Pacific 9550 storage device. During an Inspection, an engineer notices the IAN on motherboard (LOM) optical port Indicator on the rear panel of the device Is steady yellow. This indicates that data is being transmitted at a rate of 25 Gbit/s.
A financial customer purchased a Huawei flash storage system for service deployment. An engineer configured the HyperClone feature on the storage system. If the running status of a clone consistency group (CG) is "DiffCopy reverse syncing" or "Unsynchronized", the engineer cannot delete the clone CG.
Which of the following statements are false about the distributed parallel dlent (DPC) of Huawei scale-out storage products?
Assume an enterprise customer purchased several Huawei flash storage devices for service deployment. An engineer needs to configure Syslog notification on the storage system. Which of the following statements are false about configuration operations?
When delivering a scale-out storage project, Huawei engineers introduced the OceanStor Pacific parallel file system service to the customer. Which of the following statements is false about the service?
The service system needs to be backed up before performance optimization b performed on Huawei flash storage, and up to two optimization configurations can be changed at a time.
In Huawei container storage solution, CSI is short for Container Storage Interface. Which of the following statements is false about Huawei CSI?
An industry customer has purchased a Huawei OceanStor Pacific 9950 scale-out storage device for service deployment. During an inspection of the device, the location indicator of a main storage disk module is steady yellow. What is the status of the disk module?
A financial customer purchases several Huawei flash storage devices for service deployment. During routine storage management. If an engineer logs In to a storage device as a data protection administrator, which of the following operations can the engineer perform?
When delivering a Huawel OceanStor Pacific scale-out storage project, an engineer introduced the end-to-end data Integrity check technology of scale-out storage to the customer. Which of the following statements are false about this technology?
Routine management on Huawei flash storage systems involves power-on and power-off. Which of the following statements is false about power-on and power-off?
A financial customer has purchased multiple Huawei OceanProtect Backup Storage devices for service data backup protection. Which of the following statements are false about the data reduction principle of OceanProtect Backup Storage? choose all that apply
Huawei Ocean Protect Appliance adopts the key technology of CPU core grouping and intelligent scheduling, which is widely used by customers in many industries. Which of the following is the advantage of this technology?
A bank customer purchases several Huawei flash storage devices to store upper-layer Oracle database service data. If an Oracle database fault occurs, engineers need to collect Oracle alert log files to locate the fault. Which of the following commands cannot be used to query the alert log path?
To prevent misoperations from affecting services, a storage system controls user operation permissions and scopes based on user levels and roles. Which of the following is not a tenant management user role in the storage system?
An engineer can use the ______ tool to install software for Huawei storage systems. This tool can collect and evaluate storage compatibility information in one-stop mode and supports batch installation of the UltraPath software, improving the software installation efficiency.
3 Months Free Update
3 Months Free Update
3 Months Free Update