Weekend Sale - 70% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: spcl70

H13-624_V5.5 PDF

$33

$109.99

3 Months Free Update

  • Printable Format
  • Value of Money
  • 100% Pass Assurance
  • Verified Answers
  • Researched by Industry Experts
  • Based on Real Exams Scenarios
  • 100% Real Questions

H13-624_V5.5 PDF + Testing Engine

$52.8

$175.99

3 Months Free Update

  • Exam Name: HCIP-Storage V5.5
  • Last Update: Sep 14, 2025
  • Questions and Answers: 60
  • Free Real Questions Demo
  • Recommended by Industry Experts
  • Best Economical Package
  • Immediate Access

H13-624_V5.5 Engine

$39.6

$131.99

3 Months Free Update

  • Best Testing Engine
  • One Click installation
  • Recommended by Teachers
  • Easy to use
  • 3 Modes of Learning
  • State of Art Technology
  • 100% Real Questions included

H13-624_V5.5 Practice Exam Questions with Answers HCIP-Storage V5.5 Certification

Question # 6

Assume a financial customer purchased multiple Huawei OceanStor Dorado 18000 storage devices to carry service data. A Fibre Channel link exception occurred in the storage environment. Which of the following are possible causes for this exception?

A.

When a switch network is used, the configured rate of the Fibre Channel host port does not match that of the switch.

B.

The optical fiber is poorly connected or faulty.

C.

The optical module rate of host ports does not match that of front-end storage ports.

D.

The IP address of the service network port on the application server is incorrectly set.

Full Access
Question # 7

A bank customer purchases several Huawei flash storage devices to store upper-layer Oracle database service data. If an Oracle database fault occurs, engineers need to collect Oracle alert log files to locate the fault. Which of the following commands cannot be used to query the alert log path?

A.

ioscan -funC disk > /home/pvlinks_disk

B.

CRS_HOME/bin/diagcollection.sh

C.

show parameter background_dump_dest

D.

db2support outpath -d db_name -c

Full Access
Question # 8

In actual service scenarios, the HyperMetro feature of Huawei OceanStor Pacific series supports incremental synchronization. If a site fails, the site that wins arbitration continues providing services, and I/O requests change from the dual-write state to the single-write state. After the faulty site recovers, data generated during the fault can be synchronized to the recovered site.

A.

TRUE

B.

FALSE

Full Access
Question # 9

The OceanStor Pacific series storage systems support the _______ feature. This feature uses the classic token bucket algorithm to control the traffic upper limit. If local tokens are insufficient, tokens are continuously generated and added to the token bucket based on the OPS and bandwidth upper limit of the corresponding QoS control object as the rate.

Full Access
Question # 10

An engineer can use multiple common management software to configure, manage, and maintain Huawei converged storage. Which of the following statements is false about the software and corresponding functions?

A.

SmartKit provides capabilities such as alarm reporting, file upload, and remote access.

B.

DeviceManager allows the engineer to allocate storage resources, manage users, manage data protection features, monitor device performance, and manage alarms.

C.

DME IQ enables cloud-based management, remote maintenance, automatic service request creation, and prediction and prevention, comprehensively improving customers’ O&M capabilities.

D.

The command-line interface (CLI) allows the engineer to allocate storage resources, manage users, manage data protection features, monitor device performance, and manage alarms.

Full Access
Question # 11

Assume a financial customer purchases several Huawei scale-out storage devices for service deployment. Unstructured services require multiple network planes. Which statement about the network planes is false?

A.

The internal management network is used for communication between storage and management nodes, including deployment and upgrade, resource configuration, performance alarm reporting, and certificate and key update.

B.

For the file service in the Distributed Parallel Client (DPC) scenario, the back-end storage network is available for communication with compute nodes to process communication data between the DPC and Object Storage Device (OSD).

C.

The management network is used for system management and maintenance. It is connected to the customer’s management network.

D.

The service network is connected to the customer’s application system and accesses the storage through the S3, HDFS, NFS, CIFS, and POSIX interfaces.

Full Access
Question # 12

An industry customer purchased several Huawei OceanStor Pacific series scale-out storage devices for service deployment, and an engineer configured the SmartMigration feature on the storage devices. Now the engineer wants to change the split mode and migration rate of a SmartMigration task due to changes in service requirements. Which of the following SmartMigration running statuses does not allow the engineer to perform the change?

A.

Interrupted

B.

Paused

C.

Faulty

D.

Migrating

Full Access
Question # 13

An engineer wants to configure the iSCSI block service on a Huawei scale-out storage device. Which of the following operations must be performed by the engineer?

A.

Create a block storage pool.

B.

Configure the iSCSI service.

C.

Configure DPC share access on a client.

D.

Install DPC.

Full Access
Question # 14

After purchasing a Huawei OceanStor Dorado series storage system, a customer needs to configure basic storage services in the storage system. Which of the following operations are optional in the basic service configuration?

A.

Configuring connectivity between a host and the storage system

B.

Creating a port group

C.

Creating a mapping

D.

Creating a LUN group

Full Access
Question # 15

The performance of a storage system can be measured by multiple indicators. In application scenarios where the I/O size is greater than or equal to 64 KB, the ________ performance indicator is the main concern for storage performance.

Full Access
Question # 16

An engineer can use the ______ tool to install software for Huawei storage systems. This tool can collect and evaluate storage compatibility information in one-stop mode and supports batch installation of the UltraPath software, improving the software installation efficiency.

Full Access
Question # 17

During flash storage initialization, an administrator needs to change the IP address of a management network port. Which statements about the change are false?

A.

To change the IP address of the management network port on the CLI, log in to the CLI and run the "change system management_ip" command.

B.

The IP addresses of the management and maintenance network ports must be in different network segments; otherwise, there will be a route conflict.

C.

The administrator needs to apply for and activate a license before changing the IP address of the management network port.

D.

To change the IP address of the management network port on the command-line interface (CLI), the IP address of the maintenance terminal and the default IP address of the storage management network port must be in the same network segment if the administrator logs in to the system through a serial port.

Full Access
Question # 18

An industry customer has purchased a Huawei OceanStor Pacific scale-out storage system for service deployment. An engineer configures NFS file sharing on the storage system through NFSv4.0. Which of the following commands can the engineer use to switch the user view to the developer view on the command line interface (CLI)?

A.

change domain ad_manager operation=develop

B.

change dns general address=develop

C.

change user_mode current_mode user_mode=developer

D.

change nas_Idap advanced_config

Full Access