We at Crack4sure are committed to giving students who are preparing for the Huawei H19-105_V2.0 Exam the most current and reliable questions . To help people study, we've made some of our HCSA-Sales-Data Center Facility V2.0 exam materials available for free to everyone. You can take the Free H19-105_V2.0 Practice Test as many times as you want. The answers to the practice questions are given, and each answer is explained.
Which of the following are components included in the QMS model?
Select all that apply
Process operations
Leadership
Performance appraisal
Planning
Huawei's Quality Management System (QMS) framework is based on ISO 9000 principles and establishes an integrated governance structure connecting organizational leadership, strategic planning, process execution, performance evaluation, and continuous improvement.
Leadership, represented by option B, establishes quality strategies, policies, organizational accountability, management authorization, and the cultural expectations required to achieve consistent quality outcomes.
Planning, represented by option D, translates quality objectives into practical management activities. These include identifying risks and opportunities, developing quality plans, and managing changes that may affect business performance or customer satisfaction.
Process Operation, represented by option A, integrates quality requirements into core business processes. It emphasizes end-to-end quality management and cooperation with suppliers and partners to maintain consistent quality across the value chain.
Option C refers to Performance Appraisal, whereas the defined QMS component is Performance Evaluation. Performance Evaluation includes customer satisfaction measurement, user experience assessment, operational analysis, management reviews, and verification of quality management effectiveness. Performance appraisal typically concerns the assessment of individual or organizational performance and does not reproduce the framework's designated terminology.
Accordingly, A, B, and D are the three choices that correspond directly to the QMS model's named components.
Huawei Training Material — Supporting Extract
Huawei Building a QMS Framework Model Based on ISO 9000: Leadership; Planning; Support; Process Operation; Performance Evaluation; Improvement. The framework connects business leadership and quality planning with execution, performance assessment, and continual improvement.
Huawei Course Reference: Partner Quality Management — Huawei Building a QMS Framework Model Based on ISO 9000. PDF page 104; slide 10.
Verification assessment: Verified against named QMS components; performance appraisal is not the exact term performance evaluation.
Regarding the Huawei smart modular module solution, which of the following statements are correct?
Select all that apply
FusionModule800 and FusionModule500 integrate cooling and electrical control. They are highly integrated and fully prefabricated, featuring a fully enclosed aisle with wet-film humidification and supporting smart mobile management.
Huawei FusionModule800 is a modular data center solution designed for financial outlets and small enterprise data centers. It is easy to deploy, clean, and reliable, and can perfectly meet the application requirements of these scenarios.
The FusionModule2000 adopts the simplified design concept. It has low footprint and high requirements on low floors. It does not require raised floors. It supports modular deployment and supports one-click commissioning. The implementation time is shortened from 30 days to 7 days.
In the FusionModule800 and FusionModule500, fire extinguishers can be deployed in the fire extinguishing module. The built-in fire extinguishing gas can meet the fire extinguishing requirements of the entire room.
Huawei's smart modular data center portfolio provides integrated infrastructure solutions for edge computing, branch offices, and small- to medium-sized enterprise applications.
Option A describes the integrated and prefabricated architecture of FusionModule800 and FusionModule500. The solution family combines cooling, power infrastructure, environmental management, and intelligent monitoring. Wet-film humidification and aisle containment contribute to improved cooling efficiency. However, configuration-specific features should not be assumed to apply identically to every model.
Option B correctly identifies FusionModule800 as suitable for branch network rooms, edge data centers, and smaller enterprise environments. Its compact architecture reduces deployment complexity and minimizes the need for extensive onsite integration.
Option C describes FusionModule2000's simplified site requirements and rapid deployment characteristics. Reduced footprint, lower room-height requirements, horizontal airflow without raised floors, modular assembly, and one-click commissioning support deployment within approximately seven days rather than 30 days.
Option D cannot be accepted as a general statement because fire-extinguishing capacity must be matched to the protected volume and approved system configuration. A fire suppression module does not automatically establish adequate protection for an entire room.
Therefore, A, B, and C are the intended selections. Option C's phrase concerning high requirements on low floors should be corrected to low room-height requirements.
Huawei Training Material — Supporting Extract
Site Selection: Two "Low" and One "Free". Low footprint. Low- Room Height. Free of raised floor. Smart Modular Solution: TTM = 7 days.
FusionModule800 & 500: Integration and prefabrication. Aisle containment and wet film Humidification. Cold and hot isolation, improving cooling efficiency. 4-hour rapid deployment.
Huawei Course Reference: Introduction to Huawei Data Center Facility and Critical Power Solutions — Smart Modular DC 6.0; Simplified Site Selection and Simplified Deployment; FusionModule800 & 500 Integrated Design. PDF pages 48, 51, 54; slides 49, 52, 55.
True or False: Compared with a traditional switch, the load switch used in the PowerPOD 3.0 has its width reduced by 80%.
True
False
Huawei PowerPOD 3.0 employs an innovative high-density load switch design to reduce the physical footprint of its critical power distribution architecture.
The solution uses a patented flapping-wing load switch with a compact mechanical and electrical configuration. Compared with conventional load switches, the patented design reduces switch width by approximately 80%, enabling multiple switching devices to be integrated into a smaller cabinet footprint.
This reduction is significant because traditional data center power distribution arrangements require substantial floor space for input cabinets, bypass equipment, UPS cabinets, feeder cabinets, and associated electrical components.
By integrating high-density switching technology with compact UPS power modules, PowerPOD 3.0 consolidates equipment that would otherwise occupy multiple cabinets.
Huawei's representative 2.5 MW comparison demonstrates a reduction from 21 cabinets in a conventional solution to approximately 10 cabinets in the PowerPOD 3.0 configuration. This represents a reduction of approximately 50% in the power system footprint.
The smaller switch dimensions also support a simplified physical arrangement and more efficient use of data center building space.
Option A is correct because the 80% width reduction is a specified characteristic of the patented load switch.
Huawei Training Material — Supporting Extract
Innovative load switch (Flapping-wing switch).
Built-in independent switches.
Patented small-size switch, reducing width by 80%.
1 cabinet @ 600 kVA UPS with four load switches.
Footprint saving: Converged and High-density, 21 ?10 Cabinets@ 2.5 MW, Saving Footprint by 50%.
Huawei Course Reference: Introduction to Huawei Data Center Facility and Critical Power Solutions — PowerPOD 3.0: Footprint Saving, Converged and High-Density. PDF page 18; slide 19.
Verification assessment: Direct 80% load-switch width-reduction specification.
In a large-scale water-cooled chilled water data center, how many key parameters is Huawei iCooling capable of sampling?
500 +
600 +
800 +
700 +
Option D corresponds to Huawei iCooling's specified capability of collecting operational information from more than 700 sampling points in a large-scale water-cooled chilled water data center.
Huawei iCooling is an AI-based cooling optimization system designed to reduce facility energy consumption by continuously monitoring operating conditions and dynamically adjusting cooling control strategies.
The system collects information from cooling infrastructure and analyzes 19+2 key parameters associated with system performance. This information supports intelligent coordination of cooling equipment, including chillers, pumps, cooling towers, and associated control systems.
Unlike conventional manual optimization, iCooling uses extensive data collection, data governance, dynamic model training, and real-time optimization to identify energy-efficient operating configurations.
Its algorithms can evaluate approximately 1.4 million original operating combinations within one minute to determine an appropriate cooling strategy.
Optimization is triggered by relevant operational changes, including variations in IT load or ambient temperature. For suitable water-cooled chilled water applications, Huawei identifies potential PUE improvements of approximately 8% to 15%.
The distinction between sampling points and key parameters is important. The figure of 700+ refers to sampling points, while 19+2 refers to key parameters. Therefore, D is the intended examination answer, although the question should use sampling points for technical accuracy.
Huawei Training Material — Supporting Extract
Huawei iCooling@AI: 700 + sampling points, (19+2) key parameters.
Training platform: HUAWEI CLOUD; local inference.
Infer the best cooling strategy from 1.4 million original combinations in 1 minute.
Optimization conditions: IT load rate change ? 5%; ambient temperature difference ? 2°C.
Huawei Course Reference: Introduction to Huawei Data Center Facility and Critical Power Solutions — AI Enables Optimization of Water Cooling Systems. PDF page 73; slide 74.
Verification assessment: Direct 700+ sampling-points specification; question miscalls sampling points key parameters.
What are the key benefits of outdoor PowerPOD solutions?
Select all that apply
No impact on the plot ratio of DC campus, increasing the white space area by 15%+
Decoupled from the building and on-demand capacity expansion
Fast delivery, 2 months shortened to 1 week
No built-in transformer
Huawei's outdoor PowerPOD architecture places an integrated power supply and distribution system outside the main data center building, reducing the need to allocate indoor building space to supporting electrical infrastructure.
Option A describes the space-utilization advantage. Moving power equipment outdoors can make more internal building area available for IT equipment, thereby increasing the potential white-space capacity. However, the precise assertion that the campus plot ratio is unaffected and that white space increases by more than 15% is not established by the HCSA V2.0 course slides.
Option B is supported by Huawei's outdoor PowerPOD product architecture. The power system is decoupled from the data center building and supplied as a modular containerized solution, allowing additional power capacity to be deployed according to demand.
Option C describes accelerated delivery through factory integration and simplified onsite installation. Rapid deployment is a valid benefit, but the precise reduction from two months to one week is not established for outdoor PowerPOD. The HCSA course specifies two months to two weeks for PowerPOD 3.0, which is a different stated comparison.
Option D describes a configuration characteristic rather than a general customer benefit. Transformer integration depends on the electrical architecture and product configuration.
A, B, and C appear to be the intended benefit categories, but the item requires additional product-specific evidence to validate its numerical claims.
Huawei Training Material — Supporting Extract
Huawei Data Center Facility Solution Panorama: Huawei PowerPOD; FusionPower6000 (indoor and outdoor type).
Reliable, highest density and efficiency in the industry.
Converged Innovation, Ultimate Energy Saving.
PowerPOD 3.0 Time saving: Prefabricated and controllable quality, delivery time 2 months ?2 weeks.
Supplementary official product reference: https://info.support.huawei.com/Energy/info/en_US/all/docView/EDOC1100435400
Huawei Course Reference: Huawei Data Center Facility Solution Panorama; PowerPOD 3.0 Time Saving. PDF pages 21 and 74; slides 22 and 75. Supplementary Huawei Outdoor PowerPOD user manual.
Which roles are part of the SQA LBPGP role model?
Select all that apply
Safety and quality requirement practitioner
Safety and quality result guardian
Continuous improvement pusher
Safety and quality culture builder
Huawei's Service Safety and Quality Assurance (SQA) LBPGP model defines five complementary professional roles that collectively support customer satisfaction, operational safety, quality compliance, and continuous improvement throughout service delivery.
The Safety and Quality Requirement Practitioner incorporates safety and quality requirements into operational processes, conducts compliance reviews, and initiates rectification when established requirements are not satisfied.
The Safety and Quality Result Guardian maintains accountability for safety and quality outcomes during product delivery and operations and maintenance (O & M). This includes identifying operational risks, monitoring performance indicators, and preventing safety or quality incidents.
The Continuous Improvement Pusher establishes systematic improvement mechanisms, introduces quality engineering methods, and promotes corrective actions based on recurring problems and identified improvement opportunities.
The Safety and Quality Culture Builder strengthens organizational commitment to the principles of safety-first and quality-first operations through communication, training, leadership engagement, and cultural reinforcement.
All four options therefore represent formally defined LBPGP responsibilities. The model also includes the Customer Voice Listener, which captures customer requirements, coordinates issue resolution, and ensures closed-loop management of customer feedback.
Huawei Training Material — Supporting Extract
Service SQA Role Model: LBPGP Model. The five roles are Customer Voice Listener; Safety and Quality Requirement Practitioner; Safety and Quality Result Guardian; Continuous Improvement Pusher; and Safety and Quality Culture Builder. These roles work together to execute service safety and quality management, ensure delivery results, and promote continual improvement.
Huawei Course Reference: Partner Quality Management — Service SQA Role Model: LBPGP Model; Service SQA Roles and Key Business Activities. PDF pages 107–108; slides 13–14.
Verification assessment: Directly verified from the LBPGP role model.
Which are the key technologies that PowerPOD 3.0 relies on to achieve switching from normal mode to battery mode within 0 ms?
Select all that apply
Neural network algorithm scheduling technology
Hardware Clamping Patent
Independent hardware unit (hot backup unit and filter unit)
Flapping wing switch control technology
Huawei PowerPOD 3.0 incorporates specialized electrical hardware technologies that enable uninterrupted output during transitions between normal operation and battery-backed power supply.
Option B is correct because patented hardware clamping technology supports instantaneous transfer by eliminating delays normally associated with mains failure detection, inverter startup, and communication between control components.
The patented design incorporates the three-zero concept, including zero waiting, zero delay, and zero-current hot backup. These characteristics support continuity of power delivery during changes in the input supply condition.
Option C is correct because the architecture contains an independent hardware unit comprising a hot-backup unit and filtering unit. This hardware arrangement maintains transfer readiness and helps ensure reliable output when the normal supply becomes unavailable.
Option A is incorrect because neural network scheduling technology is associated with intelligent prediction and optimization rather than the fundamental instantaneous electrical transfer mechanism.
Option D references flapping-wing switching technology, which is a genuine PowerPOD 3.0 innovation. However, Huawei positions the flapping-wing load switch primarily as a high-density power distribution and footprint-saving technology, not as one of the two specific mechanisms responsible for 0 ms transfer.
Therefore, B and C correctly identify the relevant instantaneous transfer technologies.
Huawei Training Material — Supporting Extract
Independent hardware unit for 0 ms transfer.
Patented hardware clamping: “3 Zero” technologies.
Normal operation: direct power supply by the bypass, system efficiency up to 99.1%.
Mains failure: automatic transfer to double conversion mode or battery mode within 0 ms delay.
Hot backup unit independently deployed to ensure transfer reliability.
Zero Delay: There is no inverter startup delay. No communication delay.
Huawei Course Reference: Introduction to Huawei Data Center Facility and Critical Power Solutions — PowerPOD 3.0: Core Technologies, Innovative Unit with Patented Hardware Clamping. PDF page 20; slide 21.
Verification assessment: Directly supported instantaneous-transfer technologies.
Which functions are integrated into the built-in UPS unit of the FusionModule2000?
Select all that apply
Modular UPS
Equipment room monitoring
Power distribution for cooling equipment
IT cabinet power distribution
Huawei FusionModule2000 incorporates an integrated UPS architecture designed to consolidate power supply and distribution functions within a compact modular data center infrastructure. The objective is to reduce equipment footprint, simplify electrical installation, and improve the efficiency of power delivery to IT and supporting cooling equipment.
Option A is correct because the integrated solution incorporates modular UPS technology, providing flexible capacity expansion and maintainable power modules. The architecture supports a high-density UPS configuration with a rated capacity of up to 180 kW per cabinet in the course's product comparison.
Option C is correct because power distribution for cooling equipment is integrated into the solution. This removes the need for a separate cooling power distribution cabinet and supports coordinated power supply to the cooling infrastructure.
Option D is correct because IT power distribution is also consolidated within the integrated UPS architecture, enabling electrical power to be supplied to server cabinets through the integrated distribution system.
Option B is incorrect because equipment room monitoring is performed by the facility monitoring and management systems rather than being one of the three principal integrated UPS power functions.
Compared with traditional arrangements requiring separate UPS, IT power distribution, and cooling distribution cabinets, the integrated design can save one to two cabinets and reduce deployment workload.
Huawei Training Material — Supporting Extract
Core technology: integrated UPS, saving one to two cabinets and reducing workload by 50%.
Traditional: UPS + PDC; UPS — IT PDC — Cooling PDC.
Huawei: Integrated UPS.
Power space: 2~3 cabinets ? Power space: 1 cabinet.
Space saving: One to two cabinets are saved.
Simple deployment: Multiple cabinets are integrated, reducing workload by 50%.
Huawei Course Reference: Smart Modular DC 6.0 — Core Technology: Integrated UPS. PDF pages 49 and 52; slides 50 and 53.
Verification assessment: Confirmed from integrated UPS architecture.
Which of the following represent the key values of Huawei PowerPOD 3.0?
Select all that apply
Power saving
Worry free
Time saving
Space saving
Huawei PowerPOD 3.0 is a converged critical power solution designed around four core customer value propositions: footprint saving, power saving, time saving, and worry-free operation.
Option A is correct because PowerPOD 3.0 improves end-to-end electrical efficiency through its integrated power architecture and S-ECO operating mode. Huawei identifies an improvement in full-link efficiency from approximately 95.4% to 98.4%, excluding the transformer.
Option B is correct because worry-free operation is achieved through full-chain visualization, intelligent monitoring, predictive maintenance, and early identification of component deterioration. These functions support reliability and reduce unplanned service interruptions.
Option C is correct because factory prefabrication, integrated equipment design, and simplified busbar connections reduce deployment complexity. Huawei identifies a reduction in delivery time from approximately two months to two weeks.
Option D corresponds to the officially designated Footprint Saving value. High-density power modules and compact flapping-wing switches enable substantial equipment consolidation, reducing a representative 2.5 MW configuration from 21 cabinets to 10.
These four value propositions collectively address energy efficiency, operational reliability, implementation time, and infrastructure space utilization. All four answer choices are therefore correct.
Huawei Training Material — Supporting Extract
PowerPOD 3.0: Footprint saving — 50%(21?10cabinets).
Power saving — 95.4%?98.4%.
Time saving — 2months ?2weeks.
Worry free — Reactive ? Predictive O & M.
Innovative power module; Innovative load switch; S-ECO; Efficiency 98.4%@0ms transfer.
Huawei Course Reference: Introduction to Huawei Data Center Facility and Critical Power Solutions — PowerPOD 3.0: Converged & Simplified, Building a Footprint Saving, Efficient, and Reliable Power System. PDF page 17; slide 18.
Verification assessment: All four PowerPOD 3.0 value propositions identified.
In the intelligent computing era, the IT power density of data centers is increasing.
True
False
The rapid development of artificial intelligence, large language models, and high-performance computing is driving substantial increases in the electrical power density of modern data centers.
AI computing platforms require high-performance processors, accelerators, memory systems, and high-bandwidth interconnection infrastructure. These technologies concentrate greater computing capacity and electrical demand within individual equipment racks.
Huawei identifies the progression from traditional rack power densities of approximately 6–8 kW to higher-density configurations of 12–16 kW and, subsequently, 30 kW or more per rack.
This increase has major implications for data center facility architecture. Power distribution systems must support greater electrical loads, while cooling infrastructure must remove significantly higher heat densities without compromising equipment operating conditions.
Higher-density deployments also increase the importance of power system efficiency, modular scalability, intelligent cooling control, and optimized use of equipment-room space.
Huawei's PowerPOD, FusionCol, and prefabricated modular data center solutions address these requirements through high-density power conversion, efficient cooling, and simplified infrastructure deployment.
The trend is therefore not limited to increasing total data center energy consumption; it also involves concentrating more electrical power within each rack and reducing the space required per unit of computing capacity.
Option A correctly describes this fundamental industry trend.
Huawei Training Material — Supporting Extract
Development of AI drives DCs to High Power Density and Fast Service Rollout.
Data centers are moving towards high density and flexible deployment.
Power density is continuously increasing.
6-8 kW/Rack; 12-16 kW/Rack; 30+ kW/Rack.
Huawei Course Reference: Introduction to Huawei Data Center Facility and Critical Power Solutions — Data Center Industry Trends: Development of AI Drives DCs to High Power Density and Fast Service Rollout. PDF page 5; slide 6.
Verification assessment: Directly verified AI-driven increase in rack power density.
Which of the following statements about the Huawei prefabricated modular data center solution are incorrect?
Property certificates cannot be obtained for prefabricated modular data centers. Therefore, assets must be depreciated by equipment.
The FusionDC1000C uses the in-row air cooling solution.
For a data center with 1000 cabinets, the TTM of the prefabricated modular construction mode is six months, excluding the time for planning and construction application and design.
By default, the power supply module of the FusionDC1000C outside China includes a transformer.
Huawei's FusionDC prefabricated modular architecture incorporates standardized power, cooling, battery, and IT modules to accelerate construction while preserving operational reliability.
Option A is incorrect because prefabricated modular data centers are not categorically excluded from obtaining property certificates. Huawei identifies property certification as a supported characteristic of its Panshi structural architecture, subject to applicable project and regulatory requirements.
Option D is also incorrect. The FusionDC1000C power supply module distinguishes between domestic and international configurations. Huawei identifies transformer-integrated power modules for China, whereas the standard large-data-center power supply module outside China is configured without a transformer.
Option C reflects a supported deployment objective. Huawei identifies delivery of a 1,000-cabinet prefabricated data center in approximately half a year, with its broader project comparison specifying six to nine months depending on deployment arrangements.
Option B requires technical qualification. FusionDC1000C supports multiple cooling configurations, including built-in DX air conditioning in certain medium-sized IT modules and separate cooling modules using EHU-DX or fan-wall arrangements. Consequently, describing in-row air cooling as a universal characteristic of FusionDC1000C is imprecise.
A and D are the definitively incorrect statements. B should be rewritten to identify the particular module configuration.
Huawei Training Material — Supporting Extract
FusionDC1000C Power Supply Module: China, with 2~2.5 MVA transformer inside. Outside China, without transformer.
FusionDC1000C Structural Reliability: 50-year service life; Design life: 50 years; You can get a property certificate.
FusionDC1000C Architecture: Deliver 1000 cabinets DC in half a year, TTM shorten 50%+.
Huawei Course Reference: FusionDC1000C Architecture; Focus on 4 Types of Core Modules; Reliable: Panshi Structure. PDF pages 41–45; slides 42–46.
Which of the following statements correctly describe the efficiency of the UPS5000-H when operating in S-ECO mode?
Select all that apply
Efficiency > 98.5% @ 20% - 100% load
Up to 99.1%
Up to 98.5%
Efficiency > 99.1% @ 20% - 100% load
Huawei UPS5000-H is a high-efficiency modular uninterruptible power supply designed for critical power applications requiring high reliability, maintainability, and reduced energy consumption.
Its Smart Economy Control Operation (S-ECO) mode improves electrical conversion efficiency while preserving uninterrupted power delivery through rapid transfer between operating modes.
Option B is correct because Huawei specifies maximum S-ECO efficiency of up to 99.1%. This performance reduces energy losses and lowers the operating expenditure associated with UPS power conversion.
Option A represents the intended high-efficiency operating range. Huawei identifies an efficiency threshold of at least 98.5% at 20% load and illustrates a high-efficiency profile across the wider operating range. However, the precise course statement uses ?98.5% at 20% load, rather than establishing a strict greater-than threshold at every point between 20% and 100%.
Option C is incorrect as a maximum efficiency specification because the UPS5000-H can achieve approximately 99.1%, exceeding 98.5%.
Option D is incorrect because an efficiency exceeding 99.1% throughout the stated load range would contradict the specified maximum of 99.1%.
Accordingly, A and B are the intended examination selections, with A requiring corrected inequality wording for complete technical accuracy.
Huawei Training Material — Supporting Extract
UPS5000-H Green: 96% ? 99.1%. S-ECO mode, 0 ms switching. The efficiency ?98.5%@20% load.
S-ECO mode: 99.1%, saving 11% electricity cost compared with transformer-based UPS. 99.1% Extreme High Efficiency.
Huawei Course Reference: Introduction to Huawei Data Center Facility and Critical Power Solutions — UPS5000: Full Modular, AI+, Extreme Reliable and Simple O & M; S-ECO Mode. PDF pages 58, 62; slides 59, 63.
Verification assessment: 99.1% maximum and ?98.5% at 20% load; the stated > threshold is imprecise.
When an Energy Storage System (ESS) fire alarm activates but only smoke — not flame — is being emitted, which of the following is the correct response action?
Open the cabinet door, check the point of origin inside, and use a fire extinguisher to put out the fire.
Keep observing the situation remotely. Do not spray water into it for the time being, and pour water onto its surface to cool the temperature. Spray water into it after seeing open flame.
Open the valve for the water sprinkler pipe and start the water pump to inject water into the faulty ESS.
Approach the ESS to measure its temperature with your hand.
Smoke emission from an Energy Storage System (ESS) indicates a potentially hazardous battery condition involving overheating, internal electrical faults, or the initial development of thermal runaway. Immediate response must prioritize personnel safety, remote observation, and controlled emergency procedures.
Option B is the closest answer because it emphasizes maintaining remote observation and avoiding the immediate introduction of water into an ESS emitting smoke without visible flames.
However, personnel must not interpret this option as authorization to approach a smoking cabinet to apply water externally. Huawei's fire safety requirements explicitly prohibit approaching a smoking ESS to spray water because electrical faults and sparks may ignite combustible gases accumulated inside the enclosure.
The appropriate initial response involves evacuating personnel, raising emergency alarms, maintaining a safe distance, and remotely isolating the equipment where possible.
If visible fire develops, appropriately equipped emergency responders should implement the approved fire-extinguishing and cooling procedures in accordance with local fire authority requirements and site conditions.
Option A is unsafe because opening the enclosure may introduce oxygen and increase explosion risk. Option C describes an intervention that is not appropriate as an automatic initial response to smoke alone. Option D exposes personnel directly to thermal, electrical, and explosion hazards.
Huawei Training Material — Supporting Extract
Fire Handling Process: Quickly evacuate personnel. Call the fire department. Try to remotely shut down the equipment. Continuously monitor the equipment in a safe area. Take personal protection measures. Precautions for Handling Fire: Do not approach an ESS that emits smoke and spray water on it; combustible gas accumulation and electrical sparks may cause explosion. The specific fire handling process must be formulated according to local fire department requirements and onsite conditions.
Huawei Course Reference: Safety Management — Fire Handling Process; Precautions for Handling Fire. PDF pages 183–184; slides 56–57.