Labour Day Special - 65% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: c4sdisc65

H19-311 PDF

$38.5

$109.99

3 Months Free Update

  • Printable Format
  • Value of Money
  • 100% Pass Assurance
  • Verified Answers
  • Researched by Industry Experts
  • Based on Real Exams Scenarios
  • 100% Real Questions

H19-311 PDF + Testing Engine

$61.6

$175.99

3 Months Free Update

  • Exam Name: Huawei Certified Pre-sales Associate- Data Center Facility
  • Last Update: May 5, 2024
  • Questions and Answers: 225
  • Free Real Questions Demo
  • Recommended by Industry Experts
  • Best Economical Package
  • Immediate Access

H19-311 Engine

$46.2

$131.99

3 Months Free Update

  • Best Testing Engine
  • One Click installation
  • Recommended by Teachers
  • Easy to use
  • 3 Modes of Learning
  • State of Art Technology
  • 100% Real Questions included

H19-311 Practice Exam Questions with Answers Huawei Certified Pre-sales Associate- Data Center Facility Certification

Question # 6

Which of the following conditions shall be considered whencalculating the UPS rated inputcurrent?

(Multiple Choice)

A.

UPS rated output apparent power

B.

UPS operating nominal efficiency

C.

Battery inversion efficiency

D.

UPS battery charging efficiency

Full Access
Question # 7

The standard UPS5000-A is equipped with an LCD which supports multiple languages, displays system operating system in real time, and stores a maximum of () alarm records.

A.

2000

B.

2500

C.

3000

Full Access
Question # 8

Which of the following are the optional components for the UPS2000-G series (6 kVA to 20 kVA)? () (Multiple Choice)

A.

Temperature and humidity sensor

B.

Battery temperature sensor

C.

Transformer

D.

PDU

Full Access
Question # 9

The battery voltage of the UPS2000-G is 240 V for the 6-10 kVA capacity models, and is 480 V for the 15 kVA and 20 kVA capacity models.

A.

TRUE

B.

FALSE

Full Access
Question # 10

Which of the following statements are correct about UPS5000-E bypass overload capacity? (Multiple Choice)

A.

125% overload for 10 minutes

B.

125% overload for 60 minutes

C.

135% overload for a long time

D.

1000% overload for 100 ms

Full Access
Question # 11

Conformal coating can effectively reduce the failure rate of the UPS in severe conditions/ including salt mist, dust, and high temperature and humidity, which ensures its service life in severe conditions.

A.

TRUE

B.

FALSE

Full Access
Question # 12

With parallel configuration, the UPS2000-G supports the use of a single () card for multiple UPSs in parallel. (Multiple Choice)

A.

SNMP

B.

Modbus

C.

Dry contact

D.

Parallel

Full Access
Question # 13

What is the cooling capacity of a single air conditioner used by the Fusion Mod ule800? ()

A.

7.5 kW

B.

9kW

C.

11 kW

D.

12.5 kW

Full Access
Question # 14

Which of the following communication functions does the UPS5000-E support? (Multiple Choice)

A.

Dry contact card

B.

RS485

C.

SNMP

D.

RS232

Full Access
Question # 15

The Fusion Mod ule500 adopts free cooling.

A.

TRUE

B.

FALSE

Full Access
Question # 16

The optional components and features in the typical configuration solution of the FusionModule800 include ().

A.

Temperature and humidity sensor, door status sensor, water sensor, smoke sensor, and mobile app

B.

Smoke sensor, door status sensor, water sensor, alarm notification over short messages, and Huawei tablet

C.

Door magnetic switch, Water leakage, Video system. Power backup system, iBattery, Mobile APP (remote), Emergency fans

Full Access
Question # 17

What UPS configuration method does the Fusion Mod ule800 support? ()

A.

N/2N

B.

N/N+1

C.

N/N+1/2N

Full Access
Question # 18

The UPS5000-E features wide voltage and frequency input range. It can be used in severe grid environments and extend the battery service life. What's the maximum input voltage range of the UPS5000-E?

A.

305-485 V

B.

105-485 V

C.

138-485 V

Full Access
Question # 19

For 80 kW IT loads, configuring an 80 kVA UPS can meet the basic requirements.

A.

TRUE

B.

FALSE

Full Access
Question # 20

The UPS2000-G is a double conversion online UPS powered by mains in the normal operating state. A rectifier converts AC power into DC power, and then an inverter converts the rectified DC power into pure AC power to be supplied to loads. A charger is used to charge the storage battery string.

A.

TRUE

B.

FALSE

Full Access
Question # 21

The bypass module of the UPS5000-E-200K (50 kVA power module) is the same as that of the UPS5000-E-300K.

A.

TRUE

B.

FALSE

Full Access
Question # 22

For the UPS2000-G series (6 kVA to 20 kVA), the main input voltage ranges from 80 V to 280 V, and the input frequency ranges from 40 Hz to 70 Hz. A wide input range effectively reduces the battery switch times, failure probability, and battery charge/discharge times, helping improve the battery life.

A.

TRUE

B.

FALSE

Full Access
Question # 23

Which of the following UPS types does the PS5000-E (50 kVA power module) belongs to? (Multiple Choice)

A.

Industrial frequency UPS

B.

High frequency UPS

C.

Rack and tower-mounted UPS

D.

Modular UPS

Full Access
Question # 24

The UPS5000-E can realize convenient and simple N+X power supply system only by configuring a ().

A.

BSC cable

B.

Parallel cable

C.

BSC control board

D.

Parallel card

Full Access
Question # 25

Which of the following items is required when Mod Bus is adopted to manage the UPS5000-E remotely?

A.

ModBUScard

B.

Not required

C.

RS232-USB conversion interface

Full Access
Question # 26

What air conditioner configuration method does the FusionModule800 support? ( )

A.

1+0/1+1

B.

2+0/2+1

C.

1+0/1+1/2+0/2+1

Full Access
Question # 27

By default, how many POUs are configured for one cabinet of the FusionModule2000? ( )

A.

1

B.

2

C.

3

D.

4

Full Access
Question # 28

Which of the following actions does the UPS2000-G take when the main input exceeds the allowable range? ()

A.

Switch to battery mode.

B.

Switch to bypass.

C.

Initiate overvoltage protection or undervoltage protection.

D.

Initiate derating and continue operating.

Full Access
Question # 29

Multiple input/output systems can meet the requirements in customers' power grid application scenarios. What input/output systems does the 10-kVA UPS2000-G support? (Multiple Choice)

A.

Single-phase input and single-phase output

B.

Single-phase input and three-phase output

C.

Three-phase input and three-phase output

D.

Three-phase input and single-phase output

Full Access
Question # 30

The THDV of the UPS5000-A at full linear loads is ().

A.

0.01

B.

0.02

C.

0.03

D.

0.05

Full Access
Question # 31

The DC cable voltage drop must be within ( ).

A.

0.01

B.

0.02

C.

0.03

D.

0.05

Full Access
Question # 32

Which of the following is the maintenance bypass implementation mode of the UPS2000-G series (6 kVA to 20 kVA)? ()

A.

The UPS2000-G provides a built-in maintenance bypass.

B.

A PDU is configured to support a maintenance bypass.

C.

Maintenance bypass is unsupported.

Full Access
Question # 33

With high-efficiency rating, the UPS2000-G series was the first in the industry to earn Energy Star certification from the U.S.

A.

TRUE

B.

FALSE

Full Access