We at Crack4sure are committed to giving students who are preparing for the Huawei H20-923_V1.0 Exam the most current and reliable questions . To help people study, we've made some of our HCSP-Field-Data Center Facility V1.0 exam materials available for free to everyone. You can take the Free H20-923_V1.0 Practice Test as many times as you want. The answers to the practice questions are given, and each answer is explained.

Question # 6

When the mains supply is stable, the UPS5000-H mainly works in which mode after ECO is configured?

A.

Battery

B.

Normal

C.

Static bypass

D.

Maintenance bypass

Question # 7

During routine maintenance of the lithium battery cabinet, which of the following areas should be protected from electric shocks caused by exposed hands or metal objects?

A.

Battery general positive terminal

B.

Battery negative terminal

C.

Short-circuit copper bar between battery modules

D.

Battery positive terminal

E.

Battery general negative terminal

Question # 8

After the battery module is installed, the torque and insulation should be checked according to the specified requirements.

A.

True

B.

False

Question # 9

Which O&M practice is most effective for identifying cooling inefficiency caused by airflow problems in an operating data center?

A.

Disable temperature sensors to prevent false alarms

B.

Compare rack inlet temperatures, return air temperatures, and fan speed trends to detect recirculation and bypass

C.

Lower supply air temperature to the minimum possible value at all times

D.

Run humidification continuously regardless of ambient conditions

Question # 10

After the unit is powered on for the first time, it enters the compressor preheating state. To quickly perform power-on commissioning, you can manually shut down the compressor preheating.

A.

True

B.

False

Question # 11

Which of the following interfaces is used to connect the controller and the main control module of the unit?

A.

DP

B.

USB

C.

SW

D.

I2C/12v

Question # 12

The maintenance bypass switch cannot be turned on when the UPS5000-H works in normal mode.

A.

True

B.

False

Question # 13

Which of the following statements is false about the advantages of the free cooling solution for data centers?

A.

The current technology is not mature enough and should be used with caution.

B.

Has many use cases in the industry.

C.

Directly uses the cooling capacity of the outdoor cooling source, resulting in ultra-low energy consumption.

D.

Makes full use of the seasonal temperature difference of air and water sources.

Question # 14

The UPS5000-H-1200 kVA and UPS5000-H-1600 kVA have two power cabinets and one bypass cabinet, and are equipped with the MDU, ECU, and surge protection box.

A.

True

B.

False

Question # 15

Which of the following is not a scenario-based solution for Huawei data center products?

A.

FusionDC800

B.

FusionDC1000

C.

FusionModule500

D.

FusionModule2000

Question # 16

During routine maintenance of the lithium battery cabinet, which of the following procedure is true about replacing a faulty battery module?

A.

1-6-3-2-5-7-4

B.

1-3-2-6-5-7-4

C.

1-6-2-5-3-7-4

D.

1-2-3-6-5-7-4

Question # 17

After replacing the fan, choose "Menu > _____ > Performance Maintenance" on the main screen to enter the "Performance Maintenance" screen and clear the accumulated runtime of the indoor fan.

A.

Alarms

B.

Settings

C.

Running

D.

Maint

Question # 18

When the outdoor unit is installed at a position higher than the indoor unit, install an oil trap every five to six meters in the vertical direction along the gas pipe to ensure system reliability.

A.

True

B.

False

H20-923_V1.0 PDF

$33

$109.99

3 Months Free Update

  • Printable Format
  • Value of Money
  • 100% Pass Assurance
  • Verified Answers
  • Researched by Industry Experts
  • Based on Real Exams Scenarios
  • 100% Real Questions

H20-923_V1.0 PDF + Testing Engine

$52.8

$175.99

3 Months Free Update

  • Exam Name: HCSP-Field-Data Center Facility V1.0
  • Last Update: Feb 24, 2026
  • Questions and Answers: 60
  • Free Real Questions Demo
  • Recommended by Industry Experts
  • Best Economical Package
  • Immediate Access

H20-923_V1.0 Engine

$39.6

$131.99

3 Months Free Update

  • Best Testing Engine
  • One Click installation
  • Recommended by Teachers
  • Easy to use
  • 3 Modes of Learning
  • State of Art Technology
  • 100% Real Questions included