Summer Special - 65% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: c4sdisc65

ITFAS-Level-1 PDF

$38.5

$109.99

3 Months Free Update

  • Printable Format
  • Value of Money
  • 100% Pass Assurance
  • Verified Answers
  • Researched by Industry Experts
  • Based on Real Exams Scenarios
  • 100% Real Questions

ITFAS-Level-1 PDF + Testing Engine

$61.6

$175.99

3 Months Free Update

  • Exam Name: Inspection and Testing of Fire Alarm Systems Level I Exam
  • Last Update: Sep 12, 2025
  • Questions and Answers: 85
  • Free Real Questions Demo
  • Recommended by Industry Experts
  • Best Economical Package
  • Immediate Access

ITFAS-Level-1 Engine

$46.2

$131.99

3 Months Free Update

  • Best Testing Engine
  • One Click installation
  • Recommended by Teachers
  • Easy to use
  • 3 Modes of Learning
  • State of Art Technology
  • 100% Real Questions included

ITFAS-Level-1 Practice Exam Questions with Answers Inspection and Testing of Fire Alarm Systems Level I Exam Certification

Question # 6

In private mode systems, what is the audibility requirement?

A.

Minimum 75 dBA

B.

Minimum 85 dBA

C.

10 dBA above ambient

D.

15 dBA above ambient

Full Access
Question # 7

Secondary power shall automatically provide power to a protected premises system within how many seconds after the primary power fails?

A.

10

B.

30

C.

60

D.

90

Full Access
Question # 8

After the secondary power supply has operated the fire alarm system under quiescent load,the secondary power shall be capable of operating all alarm notification appliances for which length of time?

A.

5 minutes

B.

10 minutes

C.

1 hour

D.

24 hours

Full Access
Question # 9

An off-normal signal shall be initiated during which of the following travel distances of the valve control apparatus from its normal position?

A.

1/5

B.

1/4

C.

1/3

D.

1/2

Full Access
Question # 10

After 15 years from initial installation, all fixed-temperature, nonrestorable heat detectors shall be replaced or have how many detectors per 100 laboratories tested?

A.

2

B.

4

C.

6

D.

8

Full Access
Question # 11

Within what time limit shall a sprinkler waterflow alarm-initiating device activate?

A.

90 seconds

B.

100 seconds

C.

120 seconds

D.

180 seconds

Full Access
Question # 12

How often should a monitored fire alarm system be inspected for trouble signals?

A.

Weekly

B.

Monthly

C.

Semiannually

D.

Annually

Full Access
Question # 13

When shall the elevator alternate level recall function be initiated?

A.

In response to activation of a smoke detector located at the designated elevator lobby

B.

In response to activation of a smoke detector located on a floor above designated lobby

C.

When elevator Phase I recall fails to initiate

D.

With activation of a general building alarm

Full Access
Question # 14

Which three of the following are types of fire alarm control units? (Choose three.)

A.

Central station

B.

Dedicated function

C.

Protected premises

D.

Releasing service

Full Access
Question # 15

An inspector has been given a list of 45 devices and 1 fire alarm control unit that needs to be inspected at a job site. The inspector knows it takes on average about 2 minutes to inspect 1 device with documentation. Also, the inspector knows it takes 20 minutes to perform the required tests on the fire alarm control unit and get the system restored.

How long does the inspector tell the owner that the fire alarm system is expected to be impaired?

A.

1 hour, 5 minutes

B.

1 hour, 10 minutes

C.

1 hour, 30 minutes

D.

1 hour, 50 minutes

Full Access
Question # 16

How should the documentation cabinet be labeled?

A.

Fire alarm documents

B.

Fire alarm record documents

C.

System records

D.

System record documents

Full Access
Question # 17

What is the testing frequency of an engine driven generator?

A.

Weekly

B.

Monthly

C.

Semiannually

D.

Annually

Full Access
Question # 18

Which three of the following parties gets notified that the system has been restored? (Choose three.)

A.

Authority Having Jurisdiction

B.

Building occupants

C.

First responders

D.

Monitoring organization

Full Access
Question # 19

Verification of a DACT’s trouble signal to the fire alarm shall be received within a maximum of how many minutes when the primary telephone line is disconnected?

A.

2

B.

3

C.

4

D.

5

Full Access
Question # 20

Load testing of the control unit's VRLA batteries reveals that they must be replaced. Which two of the following are requirements for the replacement of VRLA batteries? (Choose two.)

A.

Batteries shall be approved by the authority having jurisdiction.

B.

Batteries shall be listed by a nationally recognized testing laboratory.

C.

Batteries shall be marked with the month and year of manufacture.

D.

Batteries shall be the same make and model as those being replaced.

Full Access
Question # 21

What is the maximum extended interval allowed for equipment to get inspected?

A.

3 months

B.

6 months

C.

12 months

D.

18 months

Full Access
Question # 22

Which is true of the phone lines on a Digital Alarm Communicator Transmitter (DACT) when no other methods are in use?

A.

Phone lines must be dedicated.

B.

Primary line should be connected to the PSTN.

C.

Test signal must be sent every 24 hours.

D.

Two separate phone lines are required.

Full Access
Question # 23

Which two of the following activities are done while visually inspecting batteries? (Choose two.)

A.

Check for corrosion or leakage.

B.

Check for proper battery voltage.

C.

Check for proper charge voltage.

D.

Check tightness of connections.

Full Access
Question # 24

Which instrument is commonly used to determine battery voltage and charging current?

A.

Battery tester

B.

Capacitance meter

C.

Multimeter

D.

Ohmmeter

Full Access
Question # 25

At which height above the floor is the sound level measured for public and private modeaudible devices?

A.

2.5 feet (0.7 meter)

B.

5.0 feet (1.5 meters)

C.

7.5 feet (2.3 meters)

D.

8.0 feet (2.4 meters)