Summer Special - 65% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: c4sdisc65

1z0-902 PDF

$38.5

$109.99

3 Months Free Update

  • Printable Format
  • Value of Money
  • 100% Pass Assurance
  • Verified Answers
  • Researched by Industry Experts
  • Based on Real Exams Scenarios
  • 100% Real Questions

1z0-902 PDF + Testing Engine

$61.6

$175.99

3 Months Free Update

  • Exam Name: Oracle Exadata Database Machine X9M Implementation Essentials
  • Last Update: Oct 15, 2025
  • Questions and Answers: 85
  • Free Real Questions Demo
  • Recommended by Industry Experts
  • Best Economical Package
  • Immediate Access

1z0-902 Engine

$46.2

$131.99

3 Months Free Update

  • Best Testing Engine
  • One Click installation
  • Recommended by Teachers
  • Easy to use
  • 3 Modes of Learning
  • State of Art Technology
  • 100% Real Questions included

1z0-902 Practice Exam Questions with Answers Oracle Exadata Database Machine X9M Implementation Essentials Certification

Question # 6

What type of SRs does the ASR Manager generate for Exadata?

A.

hardware assets

B.

backup and restore failures

C.

operating system components

D.

data entry errors

E.

software assets

Full Access
Question # 7

Which three of the following options are available for database consolidation on Exadata?

A.

Multiple pluggable databases in one or more container databases on a Virtual Machine or Bare Metal cluster

B.

Bare Metal deployment with one database per database server

C.

A single database with one or more schema per application

D.

Multiple databases spanning a Bare Metal and Virtual Machine cluster to provide resource isolation and consolidation concurrently

E.

Multiple Databases on a cluster

F.

Multiple Virtual Machine clusters supporting a single database for greatest resource isolation

Full Access
Question # 8

You must drop all celldisks on all the storage servers in an X9M-2 quarter rack as part of a reconfiguration project.

Which three statements describe the account on the storage servers which you should use and the tool that may be used to drop the celldisks?

A.

to the CELLADMIN account by calling CELLCLI on all cells using DCLI

B.

to an administrator-created storage server user with appropriate privileges on celldisk objects by calling CELLCLI on all cells using exadcli

C.

to the CELLMONITOR account using cellcli interactively on each storage server

D.

to an administrator-created storage server user with appropriate privileges on celldisk objects by calling EXACLI on all cells using exadcli

E.

to the CELLMONITOR account calling CELLCLI on all cells using DCLI

F.

to the CELLADMIN account using cellcli interactively on each storage server

Full Access
Question # 9

I/O performance of the prod database on your Exadata Database Machine has degraded slightly over the past month. The database has been allocated to the OLTP I/O Resource Management (IORM) category.

Which two monitoring tools might be useful in examining I/O performance for the prod database?

A.

OS I/O metrics using Enterprise Manager host pages for the storage servers

B.

OS I/O metrics using OS tools such as iostat on the database servers

C.

I/O-specific dynamic performance views such as v$iostat_fiie, v$iostat_function, and v$iostat_consumer_group from the prod

database instances using SQL *p1us

D.

cellcli (or exacli/exadcli) to examine storage server metrics such as database, category, ceiidisk, and griddisk

E.

OS I/O metrics using OS tools such as iostat on the storage servers

Full Access
Question # 10

In order two support a new application, you are planning to add a RAC VM cluster to an existing Oracle Exadata X9M-2 deployment.

Which two methods can be considered?

A.

Use Oracle VM Manager.

B.

Use the OEDA web-based configuration tool.

C.

Use domu_maker utility.

D.

Use the xm command.

E.

Use the OEDA Command line interface.

Full Access
Question # 11

How do ASM failure groups provide redundancy?

A.

Failure groups are created for each grid disk to ensure mirror copies are written to the same storage server for faster recovery after a physical disk failure.

B.

Failure groups contain all ASM disks in a single storage server preventing mirror copies being written to the same storage server.

C.

They ensure that the ASM Flex instances are enabled on a maximum of two database servers or VMs per cluster.

D.

Extended Redundancy mirrors data across data centers providing the highest levels of data protection.

Full Access
Question # 12

You have a script with several CELLCLI commands that must be executed on each cell in your Exadata full rack. The script must run on each cell simultaneously. How must you achieve this?

A.

Copy and execute the script on all storage servers using the EXACLI command.

B.

Copy the script to all storage servers using the dcli command and manually execute it on all storage servers using the EXACLI command.

C.

Copy and execute the script on all storage servers using the dcli command.

D.

Copy the script to all storage servers using the dcli command and manually execute it on each storage server using the DCLI command.

E.

Copy the script to all storage servers using the CELLCLI command and execute it on all storage servers in parallel using the CELLCLI command.

Full Access
Question # 13

A new Exadata Quarter Rack with 2 Database Servers and 3 HC Storage Servers and 3-phase 15kVA PDUs is being installed in a Data Center. However, the Data Center is only providing enough power for a single cable from each PDU.

Which statement is correct?

A.

The installation can go ahead, no change is required.

B.

The installation cannot proceed until two power feeds are available per PDU.

C.

A splitter cable can be used to provide power to all PDU cables.

D.

The power cables from the servers to the PDUs can be rearranged inside the rack following OECA guidance to utilize a single PDU power cable.

Full Access
Question # 14

Which two options describe the flash memory capabilities of the Exadata X9M-2 database and storage severs?

A.

4 x 6.4 TB NVMe flash cards on the High Capacity (HC) storage server

B.

4 x 6.4 TB NVMe flash cards on the database server

C.

8x 6.4 TB NVMe flash cards on the Extended (XT) storage server

D.

No flash storage on the database server

E.

8 x 6.4 TB NVMe flash cards on the Extreme Flash (EF) storage server

Full Access
Question # 15

You are working on a remote Exadata Database Machine with current software and firmware. You now need to start a storage server after hardware maintenance.

Which ILOM command starts the storage server?

A.

-> start /System

B.

-> start /SP/console

C.

-> set /SYS power_state=ON

D.

You must be physically present in the data center to start an Exadata Storage Server.

E.

-> start /SYSTEM/power

F.

-> start /SYS/power

Full Access
Question # 16

Exadata X9M enables virtualization using KVM. Which statement is true about virtualization on Exadata X9M?

A.

Up to 12 virtual guests per X9M-2 database server are supported. If the database server memory has 384GB and Exadata Secure RDMA Fabric isolation is configured 8 guests are supported

B.

Up to 12 virtual guests per X9M-2 database server are supported.

C.

Exadata X9M-8 supports up to 48 virtual guests regardless if Exadata Secure RDMA Fabric Isolation is configured.

D.

Oracle KVM Manager should be installed on at least two Database servers per Exadata rack.

E.

Virtual guests from X8 and earlier can be migrated to X9M using VM Guard.

Full Access
Question # 17

Which two statements are true about the types of Exadata X9M-2 storage servers: the High Capacity (HC) storage server, the Extreme Flash (EF) storage server and the Extended server?

A.

The HC storage server contains 12 x 18 TB hard disks, 4 x 6.4 TB PCIe flash cards, and 1.5 TB Persistent Memory.

B.

The XT storage server is an all-disk storage server with no flash, containing 12 x 18 TB hard disks, and 1.5 TB Persistent Memory.

C.

The EF storage server contains 8 x 6.4 TB PCIe flash cards.

D.

The EF storage server contains 8 x 6.4 TB PCIe flash cards and 756 GB Persistent Memory.

E.

The EF storage server contains 8 x 6.4 TB PCIe flash cards, and can be upgraded with 4 more for a total of 12.

Full Access
Question # 18

What are the two benefits of using Oracle Exadata Deployment Assistant (OEDA)?

A.

OEDA facilitates abstracting hardware.

B.

OEDA gathers configuration details and creates the Oracle Exadata Rack configuration file.

C.

OEDA is used for Oracle Exadata Database Machine, Zero Data Loss Recovery Appliance, Private Cloud Appliance, and SuperCluster.

D.

OEDA Web-based user interface cannot import OEDA XML configuration files created with the Java-based version of OEDA without conversion

E.

OEDA provides a CL1 which supports life cycle management tasks for Exadata systems only.

Full Access
Question # 19

Which three statements are true concerning the configuration or use of Enterprise Manager Cloud Control to monitor and manage Exadata Database Machine components?

A.

Cloud Control cannot monitor partitioned Exadata Database Machine systems.

B.

Storage nodes forward their SNMP traps to the Management Server process on the same storage node.

C.

Compute nodes forward their SNMP traps to the Management Server process on the same compute node.

D.

Cloud Control can monitor and manage a Database Machine storage Expansion rack.

E.

Oracle management agents must only be installed on one compute node in a Database Machine to enable monitoring and management of all compute nodes and storage nodes.

F.

Oracle management agents must only be installed on one storage node in a Database Machine to enable monitoring and management of all storage node.

Full Access
Question # 20

How many 128GB Persistent Memory DIMMS are included in Exadata X9M-2 Extended (XT) Storage Servers?

A.

0

B.

2

C.

8

D.

12

Full Access
Question # 21

You are hardening the security posture of your Exadata Database Machine. Before disabling ssh access to the storage servers, what should you do to enable REST access to the MS process?

A.

Install Oracle Rest Data Services on each Database server and install the MS APEX application.

B.

The MS Process on the storage servers is natively endowed with REST services, but are not enabled by default.

C.

Install Oracle Rest Data Services on each Storage server and install the MS APEX application.

D.

The MS Process on the storage servers is natively endowed with REST services and are enabled by default, however, appropriate roles and users should be created to ensure security.

Full Access
Question # 22

You have configured a multirack Database Machine with two X9M-8 full racks all in a single cluster and storage grid comprising a total of 4 X9M-8 Database servers and 28 X9M-8 Storage servers.

Which two options are true regarding the servers on which Enterprise Manager agents must be deployed in order to monitor all components of this multirack configuration?

A.

on at least two storage servers in both racks

B.

on only one database server in both racks

C.

on all database servers in the first rack

D.

on all storage servers in both racks

E.

on all database servers and at least two storage servers in both racks

F.

on all database servers in the second rack

G.

on all database servers in both racks and one storage server in each rack

Full Access
Question # 23

Examine these commands:

1. Execute "crscti stop cluster -all" as the grid user from one database server.

2. Execute "crscti stop cluster -all" as root from one database server.

3. Power off all network switches.

4. Execute "crscti stop cluster" as root from one database server.

5. Execute "crscti stop cluster" as the grid user from one database server.

6. Power off the rack using the power switches on the PDUs.

7. Execute "shutdown -h now" on all database servers.

8. Execute "shutdown -h now" on all Exadata storage servers.

Which is the correct order or the required commands to completely power off an Exadata Database Machine in an orderly fashion?

A.

5, 8, 7, and 6

B.

4, 7, 8, 3, and 6

C.

2, 8, 7, 3, and 6

D.

2, 7, 8, and 6

E.

1, 8, 7, 3 and 6

Full Access
Question # 24

What is the minimum Exadata System Software version required for Exadata X9M?

A.

20.1.1.0.0

B.

19.2.1 0.0

C.

21.2.0.0.0

D.

19.3.0.0.0

E.

18.1.3.0.0

F.

21.3.0.0.0

Full Access
Question # 25

Which are two correct statements about backing up Exadata Database Machine?

A.

Backup of the Oracle Cluster Registry, which also contains Voting Disk information, is automatically maintained on the file system of the first database server.

B.

Backing up Exadata Storage Server Software is critical for restoration.

C.

For high availability, system area can be on the first two disks and M.2 devices.

D.

The M.2 disk is hot pluggable and can be replaced when the power is on, but you will have to restore the system data manually.

E.

Use a snapshot-based backup of an Oracle Exadata Database Machine database server software.

Full Access