Summer Special - 65% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: c4sdisc65

210-015 PDF

$38.5

$109.99

3 Months Free Update

  • Printable Format
  • Value of Money
  • 100% Pass Assurance
  • Verified Answers
  • Researched by Industry Experts
  • Based on Real Exams Scenarios
  • 100% Real Questions

210-015 PDF + Testing Engine

$61.6

$175.99

3 Months Free Update

  • Exam Name: VCE Vblock System Deployment and Implementation – Virtualization
  • Last Update: Sep 12, 2025
  • Questions and Answers: 93
  • Free Real Questions Demo
  • Recommended by Industry Experts
  • Best Economical Package
  • Immediate Access

210-015 Engine

$46.2

$131.99

3 Months Free Update

  • Best Testing Engine
  • One Click installation
  • Recommended by Teachers
  • Easy to use
  • 3 Modes of Learning
  • State of Art Technology
  • 100% Real Questions included

210-015 Practice Exam Questions with Answers VCE Vblock System Deployment and Implementation – Virtualization Certification

Question # 6

During a deployment of a Vblock System 320, the customer has requested the installation of multiple third-party management virtual machines in the AMP. After multiple days of monitoring and data collection, the vCenter server and its respective database server stop responding.

What would cause the problem?

A.

Thin provisioned disk format caused the data store to run out of space.

B.

The NFS.HeartbeatTimeout parameter was set too high.

C.

The vCenterVirtualCenter.VimPasswordExpirationInDays parameter expired.

D.

The third-party application services have stopped responding.

Full Access
Question # 7

You are implementing 32 new UCS B230 M3 blades into an existing Vblock System with 16 blades. After powering the new blades on, and migrating them to the Cisco Nexus 1000V, you notice that half of the new blades no longer respond to any network traffic.

What is the cause?

A.

There is insufficient vSphere licensing to license the new hosts.

B.

There is insufficient Cisco licensing to license the new hosts.

C.

The network drivers need to be updated.

D.

The Cisco Nexus 1000V is limited to 32 hosts.

Full Access
Question # 8

You ordered additional SAS drives to increase the capacity of your Vblock System 300.

What is the VCE recommended RAID configuration?

A.

RAID1 (4+4)

B.

RAID5 (4+1)

C.

RAID6 (6+2)

D.

RAID5 (7+1)

Full Access
Question # 9

A DNS server is not reachable from the vCenter server.

Which file would you need to modify to communicate properly with the vCenter infrastructure?

A.

networks

B.

lmhosts.sam

C.

services

D.

hosts

Full Access
Question # 10

Which three configurable settings are available directly through the DCUI? (Choose three.)

A.

IP address

B.

date

C.

firewall ports

D.

hostname

E.

VLAN ID

Full Access
Question # 11

Which statement is correct about using VMware Inventory Services?

A.

It tracks virtual machine locations in the data center.

B.

It improves administrative user performance and reduces traffic with the vCenter.

C.

It tracks data center objects and performs reports.

D.

It improves virtual machine responsiveness.

Full Access
Question # 12

You experience problems after initially powering on a Vblock System with a mini AMP at a customer site. The vCenter services start properly but there is no network connectivity for the virtual machines. You determine that the virtual machines do not boot up in the correct order.

According to VCE best practice, what should be the virtual machine startup configuration in a Vblock System with a mini AMP?

A.

VSM-1, SQL Server, vCenter Server, VUM Server, VSM-2, Array Management Server

B.

SQL Server, vCenter Server, Array Management Server, VUM Server, VSM-1, VSM-2

C.

Array Management Server, VSM-1, vCenter Server, SQL Server, VUM Server, VSM-2

D.

vCenter Server, VUM Server, SQL Server, VSM-1, VSM-2, Array Management Server

Full Access
Question # 13

In a standard Vblock System 300 configuration with two vHBAs, a single SAN fabric has failed.

How will the hosts be impacted?

A.

Both vHBAs will lose a single path to all storage devices on that SAN fabric.

B.

A single vHBA will lose all paths to some of the storage devices on that SAN fabric.

C.

A single vHBA will lose all paths to all storage devices on that SAN fabric.

D.

Both vHBAs will lose a single path for some of the storage devices on that SAN fabric.

Full Access
Question # 14

Your vSphere environment has two virtual machines configured to use the same VLAN and subnet. The hosts in the cluster are set up to use one DV switch. You want to ensure that the VMs communicate properly on the network and with each other regardless which host they use.

Which action will accomplish this task?

A.

Consult with your network team to ensure that the ESXi hosts use common routers and switches in your data center environment.

B.

Ensure the ESXi hosts load balancing policy is configured to route based on source mac hash.

C.

Ensure the ESXi hosts load balancing policy is configured to route based on the originating virtual port ID.

D.

The vNic DVPort group must be configured to be the correct setting on both virtual machines for the VLAN they are using.

Full Access
Question # 15

You enabled access to the ESXi shell. Administrators now complain that they cannot log in to the ESXi shell although you are still logged on.

What would cause this problem?

A.

The other administrators do not have proper permissions.

B.

The number of connections exceed the limit.

C.

The ESXi shell timeout setting was increased from the default setting of 0.

D.

There is an invalid IP setting on the host.

Full Access
Question # 16

A customer requests that you join the management virtual machines to their domain, and modify the required services and databases to use a provided service account. After performing the requested actions, the VMware Update Manager plug-in will not enable and returns the following error

There was an error connecting to VMware vCenter Update Manager server name8084. Database temporarily unavailable or has network problems.

The vpxclient.log contains the error shown below

Loaded plugin from CProgram Files (x86)VMwareInfrastructureVirtual Infrastructure ClientPluginsUpdate Manager 4.0vimIntegrityClient.dll Extension.Key - com.vmware.vcIntegrity

[Update MSoapTran] 2013-07-15 101954.225 Invoke 1 Finish RetrieveVcIntegrityContent on VcIntegrityIntegrity.VcIntegrity [192.168.0.18084] - Serial0.001, Server000.021 [ERROR]

Vmomi.Fault.DatabaseError Database temporarily unavailable or has network problems.

Which solution will resolve this problem?

A.

Modify the user account permissions on the VMware Update Manager server to include Logon as a service.

B.

Modify the ODBC connection used by VMware Update Manager to use SQL authentication.

C.

Remove and re-register the VMware Update Manager plug-in.

D.

Change the VMware Update Manager Service to log on to the remote database as a Windows account with administrator privileges.

Full Access
Question # 17

In a Vblock 320 Unified Networking environment, a UCS service profile is unable to locate its boot device.

Which two statements are valid troubleshooting steps? (Choose two.)

A.

Verify that the targets in the SAN boot policy match the zoning and the masking on the array.

B.

Verify that the vHBAs are logging into the SAN fabrics by examining the Fabric Login (FLOGI) database on the Cisco MDS switches.

C.

Verify that PowerPathVE can see all paths to the device.

D.

Verify that the vHBAs are logging into the SAN fabrics by examining the Fabric Login (FLOGI) database on the Cisco Nexus 5000 series switches.

Full Access
Question # 18

The CIO of your organization requests an audit of all user logins to vCenter with the vSphere client.

Which action will allow you to provide this information?

A.

Run the event_export.sql script in SQL Management Studio on the vCenter database.

B.

Connect the vSphere client to the syslog virtual machine and export events.

C.

Connect the vSphere client to vCenter and export events.

D.

Use the vm-support command on the ESXi host to generate the log bundle.

Full Access
Question # 19

You place a data store into maintenance mode and the process hangs at one percent.

Which two solutions will resolve this problem? (Choose two.)

A.

Verify if storage DRS is disabled on the disk and enable it if necessary.

B.

Verify if there are any storage rules that are preventing storage DRS from making migration recommendations and correct them.

C.

Increase the number of failover hosts in the cluster DRS configuration.

D.

Restart remote management agents on all the hosts in the cluster.

Full Access
Question # 20

You are testing DRS as part of the Vblock System 320 deployment and have placed the ESXi server into Maintenance mode. After several minutes, the ESXi server has not completed the transition into Maintenance mode.

Which two actions should you perform? (Choose two.)

A.

Manually shut down the VMs when you put an ESXi server into Maintenance mode.

B.

Verify that DRS is in fully automatic mode.

C.

Verify VMware HA is configured because DRS requires it to transition the VMs.

D.

Verify vMotion is properly configured because DRS requires it to transition operational VMs.

Full Access
Question # 21

Which two methods would you use to deploy an ESXi image created with Image Builder CLI? (Choose two.)

A.

using Symantec Ghost

B.

using a USB drive

C.

burning it to an installation DVD

D.

using the Auto Deploy feature in vCenter Server

Full Access
Question # 22

You are asked to restore a virtual machine from a SAN array snapshot.

Which two actions must you perform to present the LUN to the ESXi host to make the data available? (Choose two.)

A.

Force mount the copy of the LUN if you are sure the original is not in use.

B.

Resignature the copy of the LUN if the original is still in use.

C.

Restore the LUN to the ESXi host.

D.

Add the copy of the LUN to the ESXi host using the format option.

Full Access
Question # 23

You are asked to upgrade the version of the Cisco Nexus 1000V software on the Vblock System 320.

Which component are you upgrading on the hypervisor?

A.

Service Console

B.

Virtual Supervisor Module (VSM)

C.

Virtual Ethernet Module (VEM)

D.

Virtual Network Interface Card (vNIC)

Full Access
Question # 24

According to the VCE Vblock System Upgrade Guide for vSphere 5.1, which two steps would be taken when upgrading vCenter to 5.1? (Choose two.)

A.

Upgrade the host to ESXi 5.1.

B.

Make a full backup of the vCenter Server database on the AMP.

C.

Make a full backup of the vCenter Inventory Service database on the AMP.

D.

Install Microsoft SQL 2008 SP3 on the Single Sign-On (SSO) virtual machine.

Full Access
Question # 25

According to the VCE Logical Build Guide, what is the recommended installation location for VMware Update Manager and its database in a Vblock System?

A.

Install the application and database on the vCenter server.

B.

Install the application and database on a standalone server.

C.

Install the application on the vCenter server and the database on a dedicated SQL server.

D.

Install the application on a standalone server and the database on a shared SQL server.

Full Access
Question # 26

Which CDDVD connection mode would be used only for remote client device access?

A.

Emulate IDE

B.

Host Device

C.

Passthrough IDE (raw)

D.

Data store ISO File

Full Access
Question # 27

You are working with a customer that has just implemented vCenter 5.1 and Single Sign-On in their Vblock System. After the upgrade, the customer is now unable to logon to vCenter using user accounts in the Sales domain. User accounts in the Corp domain continue to log in as expected, but are not able to configure Single Sign-On.

Which two explanations describe the behavior that the customer is experiencing? (Choose two.)

A.

By default, users in the local operating system Administrators group can log in to the vSphere Web Client and vCenter Server. These users cannot configure Single Sign-On or view the Single Sign-On management interface in the vSphere Web Client.

B.

By default, the vCenter Single Sign-On administrator user is admin@System-Domain. This user can log in to the vSphere Web Client to configure Single Sign-On and add accounts to manage Single Sign-On if necessary. This user cannot view or configure vCenter Server.

C.

If you are logged in as a domain account user, the default Active Directory identity sources are discovered automatically during vCenter Single Sign-On installation. If you are logged in as a local account user, Active Directory identity sources are not discovered automatically during vCenter Single Sign-On installation.

D.

The local operating system (localhost or hostname) users are added as an identity source.

Full Access