Summer Special - 65% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: c4sdisc65

2V0-13.25 PDF

$38.5

$109.99

3 Months Free Update

  • Printable Format
  • Value of Money
  • 100% Pass Assurance
  • Verified Answers
  • Researched by Industry Experts
  • Based on Real Exams Scenarios
  • 100% Real Questions

2V0-13.25 PDF + Testing Engine

$61.6

$175.99

3 Months Free Update

  • Exam Name: VMware Cloud Foundation 9.0 Architect
  • Last Update: Sep 12, 2025
  • Questions and Answers: 60
  • Free Real Questions Demo
  • Recommended by Industry Experts
  • Best Economical Package
  • Immediate Access

2V0-13.25 Engine

$46.2

$131.99

3 Months Free Update

  • Best Testing Engine
  • One Click installation
  • Recommended by Teachers
  • Easy to use
  • 3 Modes of Learning
  • State of Art Technology
  • 100% Real Questions included

2V0-13.25 Practice Exam Questions with Answers VMware Cloud Foundation 9.0 Architect Certification

Question # 6

The architect documented a requirement for 99.95% high availability to meet the customer's resiliency needs.

Which two physical design decisions will help meet this requirement in the management domain? (Choose two.)

A.

Management Port Group: Route based on physical NIC load

B.

Host Overlay DHCP Scope Lease: 14 Days

C.

Physical Switch MTU: 9000

D.

vSAN Cache Tier Sizing: 800GB

E.

Host isolation response: Power Off and restart VM

Full Access
Question # 7

Which configuration should the architect recommend as part of the design of a VMware Cloud Foundation (VCF) solution to ensure optimal performance in a multi-tenant environment?

A.

Use a single large datastore for all tenants to simplify management.

B.

Configure all workloads to operate on a single ESXi host to minimize network latency.

C.

Implement vSAN with tiered storage policies to ensure high I/O performance and low latency for tenant workloads.

D.

Allow an unlimited number of virtual machines per host to consume all available resources.

Full Access
Question # 8

An architect is designing for a greenfield VMware Cloud Foundation (VCF) solution. This would be the first VCF Fleet in the VCF solution, and the customer would like to start with a minimal footprint with the option to scale up and out later.

Which VCF Operations deployment model should the architect choose?

A.

Advanced

B.

High Availability

C.

Simple

D.

Standard

Full Access
Question # 9

An organization is evacuating their current datacenter and moving all workloads to a new datacenter. The organization has a total of 800 workloads to move, and the migration must be completed with no downtime within a planned change window that is scheduled to occur in four weeks.

What migration method will meet the requirements?

A.

Cross vCenter vMotion

B.

HCX OS Assisted Migration

C.

HCX Bulk Migration

D.

HCX Replication Assisted vMotion

Full Access
Question # 10

An architect is designing a new VMware Cloud Foundation (VCF) solution. They are meeting with the key stakeholders and subject matter experts (SMEs) for the first time as part of the requirements gathering process. The following information has been shared with the architect prior to the meeting:

    Names and job titles of the attendees

    Project timelines and budget

What step should the architect perform as part of this initial requirements gathering workshop?

A.

Open the meeting with a diagram of the VCF topology that must meet the customer requirements in order to start a discussion.

B.

Ask questions to agree on the key product features the SMEs want from the design.

C.

Open the meeting with a list of the VCF design decisions from the public documentation to agree on any required changes.

D.

Ask questions to start a discussion on the business objectives and desired outcomes.

Full Access
Question # 11

During a requirements gathering workshop, several business and technical requirements were captured from the customer.

Which requirement will be classified as a Business Requirement?

A.

The solution must provide the best end-user experience.

B.

The solution must allow the migration of legacy server infrastructure.

C.

The solution must consider security and resiliency to ensure business continuity.

D.

The solution must provide a component-level SLA of 99.9% or higher.

Full Access
Question # 12

Constraint: Existing stretched cluster model must be used.

Requirement: Minimize management infrastructure downtime.

Which Supervisor deployment model supports the design?

A.

Three Management Zone Supervisor deployment with HA control plane

B.

Single Management Zone Supervisor deployment with HA control plane

C.

Three Management Zone deployment with Simple Availability control plane

D.

Single Management Zone Supervisor deployment with Simple Availability control plane

Full Access
Question # 13

An architect is responsible for designing a new VMware Cloud Foundation (VCF)-based Private Cloud solution. During the requirements gathering workshop with key customer stakeholders, the following information was captured:

    The solution must support a yearly workload growth of up to 10%.

When creating the design document, which design quality should be used to classify the stated requirements?

A.

Performance

B.

Availability

C.

Manageability

D.

Security

Full Access
Question # 14

Discovery: Multiple business units (some from acquisitions) with separate AD instances. Each unit operates independently and requiresdedicated development environments.

Requirement: Provide self-service provisioning through VCF Automation.

Which two design decisions should be included? (Choose two.)

A.

All tenants will be configured to use the corporate AD instance for authentication.

B.

All tenants will be configured to use their dedicated AD instance for authentication.

C.

A VCF Automation tenant will be created for each business unit.

D.

A VCF Automation project will be created for each business unit.

E.

All projects will be configured to use their dedicated AD instance for authentication.

Full Access
Question # 15

An architect is responsible for designing a VMware Cloud Foundation (VCF)-based solution for a customer. During a discovery workshop, the following requirements were stated by the customer:

• All applications/workloads designated as business critical have a Recovery Point Objective (RPO) of 1 business hour.

• The infrastructure components of the VCF solution must have a Recovery Time Objective (RTO) of 4 business hours.

In the context provided, what does the RTO determine?

A.

The maximum tolerable amount of time allowed before an application/service should be recovered to a usable state

B.

The maximum amount of data loss that can be tolerated

C.

The minimum tolerable amount of time allowed before an application/service should be recovered to a usable state

D.

The minimum amount of data loss that can be tolerated

Full Access
Question # 16

An architect is designing a VMware Cloud Foundation (VCF) fleet. The following information has been provided by the customer:

    Due to budget constraints, the solution must utilize the existing server hardware.

    The existing server hardware consists of server models from the same vendor but different generations.

    There are ten servers available for use in this solution.

    Management and Business workloads should be hosted in different clusters.

What design decision should the architect make for the lifecycle management of the solution based on this information?

A.

Use a single vSphere Lifecycle Manager composite image for the management domain cluster.

B.

Use separate vSphere Lifecycle Manager composite images for the management and workload domain clusters.

C.

Use vSphere Lifecycle Manager baselines for the management domain cluster.

D.

Use a single vSphere Lifecycle Manager composite image for the management and workload domain clusters.

Full Access
Question # 17

As part of a design for a VMware Cloud Foundation (VCF) solution, an architect has documented the following dependencies and constraints:

    CONSOOl - Internet access will not be permitted from anywhere within the VCF solution.

    CONS002 - The password must not be stored in plain text anywhere within the VCF solution.

    DEP001 - The customer must make the required VCF binaries accessible to the VCF Installer appliance during the deployment phase.

Which design decision should the architect include in the design for the download of the VCF binaries?

A.

The VCF Installer appliance will be configured to connect to an online depot.

B.

The VCF Installer appliance will be configured to connect to an offline depot.

C.

The Bundle Transfer Utility will be used on the VCF Installer appliance.

D.

The VCF Download Tool will be used on the VCF Installer appliance.

Full Access
Question # 18

A customer is deploying VMware Cloud Foundation (VCF) in an enterprise environment. During a series of workshops with stakeholders, the following requirements were identified:

    The network solution must be capable of complete logical isolation.

    The network solution must be capable of supporting independent upgrade cycles for network stacks.

    The network solution must be capable of tenant-specific customization of NSX configurations.

The architect has made the following design decisions:

    The solution will consist of a single VCF instance.

    The solution will include a management domain and two workload domains.

Based on the scenario, which additional design decision meets all of the stated requirements?

A.

Deploy NSX only in the management domain and use VLAN-backed segments in the workload domains.

B.

Use a global NSX Federation configuration across workload domains.

C.

Use a shared NSX instance across both workload domains.

D.

Deploy a dedicated NSX instance per workload domain.

Full Access