Weekend Special Sale - 75% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: 75special

Practice Free 3V0-12.26 Advanced VMware Cloud Foundation 9 Architect Exam Questions Answers With Explanation

We at Crack4sure are committed to giving students who are preparing for the VMware 3V0-12.26 Exam the most current and reliable questions . To help people study, we've made some of our Advanced VMware Cloud Foundation 9 Architect exam materials available for free to everyone. You can take the Free 3V0-12.26 Practice Test as many times as you want. The answers to the practice questions are given, and each answer is explained.

Question # 6

An architect is designing an identity management solution that addresses the following requirements and constraints:

    A single fleet that extends across seven VMware Cloud Foundation (VCF) instances.

    The VCF instances are located in two geographically separated data centers.

    The design should use the minimum footprint required for identity management.

Which two design decisions meet the requirements? (Choose two.)

A.

Deploy VCF Identity Broker in a Management Domain.

B.

Deploy VCF Identity Broker in the Workload Domains.

C.

Deploy seven VCF Identity Brokers in Embedded mode.

D.

Deploy VCF Identity Broker in VCF Management Services.

E.

Deploy two VCF Identity Brokers in VCF Management Services.

Question # 7

An architect is creating a design for a VMware Cloud Foundation (VCF) private cloud.

The solution must provide:

    Protection against a single rack failure scenario.

    Maximum useable disk space possible.

Constraints include:

    vSAN ESA as principal storage.

    A single cluster of 16 ESX hosts.

    There are a total of four racks available.

Which three design choices should the architect recommend to meet the requirements? (Choose three.)

A.

Rack 16 ESX hosts in equal numbers evenly across four racks. All racks of hosts will be actively used.

B.

Implement a vSAN ESA Storage Policy that uses RAID-6.

C.

Implement a vSAN ESA Storage Policy that uses RAID-5.

D.

Configure each host as a vSAN Fault Domain.

E.

Group hosts within each rack into a vSAN Fault Domain.

F.

Rack 16 ESX hosts in equal numbers evenly across four racks. The fourth rack of hosts will be reserved as hot spares.

Question # 8

An architect is reviewing the requirements gathered from an initial client discussion:

    The architecture must provide a resilient multi-site topology.

    The solution must scale by 20 percent over the next three years.

    Application availability must experience almost zero downtime, and ideally no downtime.

    The solution must be compliant with industry regulations (PCI, HIPAA etc).

    The storage network must have a minimum latency of 10 milliseconds prior to path failover.

    Cluster nodes must scale when compute resources are sustained at 70 percent for 5 business days.

    The database server must support a minimum of 15,000 transactions per second.

Which three requirements are Functional requirements? (Choose three.)

A.

The database server must support a minimum of 15,000 transactions per second.

B.

The architecture must provide a resilient multi-site topology.

C.

The solution must scale by 20 percent over the next three years.

D.

Application availability must experience almost zero downtime, and ideally no downtime.

E.

Cluster nodes must scale when compute resources are sustained at 70 percent for 5 business days.

F.

The storage network must have a minimum latency of 10 milliseconds prior to path failover.

Question # 9

An architect is designing a new VMware Cloud Foundation (VCF) Infrastructure. The organization has defined the following requirements for the new production workload domain storage tier:

    The storage solution must utilize RAID-6 Erasure Coding to meet strict application latency SLAs.

    To simplify hardware lifecycle management, the storage architecture must be single-tier, eliminating the distinction between cache and capacity drives.

    The cluster must support future expansion using vSAN Storage Clusters.

Based on these requirements, the architect has made the design decision to deploy the vSAN Express Storage Architecture (ESA) Storage Model .

Which design implication is mandatory for this decision?

A.

The physical fabric must support a minimum of 100 Gbps.

B.

The ESX hosts must utilize Tri-Mode storage controllers.

C.

The physical disks must be arranged into a minimum of two Disk Groups per host.

D.

All storage devices in the cluster must be NVMe drives.

Question # 10

An architect wants to track and alert on combined network and CPU consumption as a percentage for each Virtual Machine (VM). The following formula is to be used:

Utilization = (% CPU + % Network) / 2

Which design decision meets the requirements?

A.

Design a Notification Definition using a Super Metric.

B.

Design a Notification Definition using Calculated Metrics.

C.

Design an Alert Definition using a Super Metric.

D.

Design an Alert Definition using Calculated Metrics.

Question # 11

An architect is designing a VMware Cloud Foundation (VCF) private cloud that is integrated with VCF Automation to support multiple internal departments.

The following requirements were provided:

    Some departments build and operate full application stacks, while others only deploy standardized virtual machines through pre-approved templates.

    Central IT must enforce quota limits, approval workflows, and cost visibility per department, while ensuring strict isolation between departments and least operational overhead.

    The solution must implement the minimum number of organizations to address the above requirements.

Which two tenant design decisions satisfy the requirements? (Choose two.)

A.

Use VM Apps Organizations for departments consuming standardized virtual machines only.

B.

Create multiple Organizations, one per department, to enforce isolation and governance boundaries.

C.

Use All Apps Organizations for departments managing full application lifecycles.

D.

Place all departments into a single Organization and separate them using multiple Regions.

E.

Deploy a single Organization and rely on project-level RBAC to isolate departments.

Question # 12

An architect is responsible for designing a VMware Cloud Foundation (VCF) Private Cloud solution. During a requirements gathering workshop, the customer supplied the following information:

    The solution must support the monitoring of all existing workloads.

      There are currently 15,000 virtual machine workloads running within the existing environment.

      All infrastructure components will also be monitored by the solution.

The solution must ensure that the 99.9% uptime Service Level Agreement can be met.

The solution must be resilient to a single fault domain failure.

The following logical design decisions have been made within the design:

    Deploy the VCF Operations cluster following the High Availability Model.

The following table is from the VCF Operations sizing guide:

Small

Medium

Single-Node Object Maximum

10,000

30,000

Single-Node Max Collected Metrics

1,600,000

5,000,000

Maximum Nodes in a cluster

2

8

Multi-Node Object Maximum

6,000

17,000

Multi-Node Max Collected Metrics

1,400,000

4,000,000

Maximum Objects in a Cluster

12,000

136,000

Maximum Metrics in a Cluster

2,800,000

32,000,000

Maximum Nodes for Continuous Availability per Fault Domain

1

4

Given the information above, which three physical design decisions meet the stated requirements? (Choose three.)

A.

Enable Continuous Availability in VCF Operations.

B.

Apply a vSphere Distributed Resource Scheduler (DRS) affinity rule to the VCF Operations cluster nodes.

C.

Enable High Availability in VCF Operations.

D.

Apply a vSphere Distributed Resource Scheduler (DRS) anti-affinity rule to the VCF Operations cluster nodes.

E.

Deploy four medium VCF Operations nodes.

F.

Deploy two small VCF Operations nodes.

Question # 13

An enterprise architect is designing the physical networking architecture for a greenfield VMware Cloud Foundation (VCF) deployment in a single data center. The deployment includes a management domain and multiple workload domains, utilizing NSX for software-defined networking with Geneve overlay encapsulation. NSX Edge nodes will handle North/South routing and services.

Requirements:

    Scalable, non-blocking fabric with predictable oversubscription and low latency.

    Support for high-throughput traffic including vSAN, vMotion, and NSX overlay.

    End-to-end jumbo frame support for efficiency.

    No dependency on physical multicast routing or snooping for overlay (BUM) Broadcast, Unknown-unicast, and Multicast replication.

    Redundant connectivity from hosts to the fabric.

Constraints:

    Existing Top-of-rack switches are limited to 25 GbE host-facing ports.

    The physical network does not support multicast.

    Future expansion to multiple racks and higher port speeds (25/100 GbE) is anticipated.

What are the four design decisions that fit the architecture ' s physical design? (Choose four.)

A.

Enable jumbo frames MTU 9190 end-to-end across all switch ports, inter-switch links, and VLAN Layer 3 interfaces used for host transport traffic.

B.

Configure head-end replication mode for BUM traffic in the NSX overlay transport zone to eliminate multicast dependency.

C.

Each ESX host has at least two 25 GbE physical NICs, connected redundantly to separate leaf (ToR) switches.

D.

Use multicast replication mode in the NSX overlay transport zone to leverage physical network multicast for BUM traffic.

E.

Each ESX host with at least two 10 GbE physical NICs, connected redundantly to separate leaf (ToR) switches.

F.

Deploy a leaf-spine topology with Layer 3 routing BGP between leaf and spine layers for scalable ECMP routing.

G.

Implement Layer 2 extended across aggregation switches for VLAN spanning.

Question # 14

An Architect was provided with a list of findings and statements collected during a presales meeting with the customer.

Which two statements should be classified as requirements in the conceptual model? (Choose two.)

A.

The architecture must provide a resilient multi-site topology.

B.

A single point of failure exists in the networking infrastructure.

C.

The design must use the existing shared storage array.

D.

The solution must scale by 20 percent over the next three years.

E.

Enough unused capacity is available on the storage array for the new workloads.

Question # 15

An architect is designing a VMware Cloud Foundation (VCF) Fleet with multiple workload domains. To reduce hardware costs, an IT executive proposes deploying Fleet Management services and other core management components within one of the shared workload domains and eliminating a dedicated management domain.

Which design principle is recommended for deploying VCF?

A.

Consolidate management by relocating it into one of the shared workload domains.

B.

Use a separate vCenter outside of VCF for lifecycle services.

C.

Consolidate the workload domain by relocating into the management domain.

D.

Remove the management domain after the initial installation.

Question # 16

The following information has been collected from an architect during initial VMware Cloud Foundation (VCF) design discussions:

    Applications must be designed to tolerate the failure of a single data center.

    Service account passwords must be stored and retrieved from the company password vault.

    The self service catalog must meet the Service Level Objective (SLO) of 75% successful requests measured over a 12 month period.

    Management plane applications must return to operation (RTO) in under 10 minutes.

    Third-party pen testing must be executed against the solution yearly with a pass rate of 80 percent or higher.

    The solution must provide the ability for users to view and track the progress of their requests.

    All Identity management must use an external SAML based identity provider.

Which four statements are Functional Requirements? (Choose four.)

A.

Service account passwords must be stored and retrieved from the company password vault.

B.

All Identity management must use an external SAML based identity provider.

C.

Applications must be designed to tolerate the failure of a single datacenter.

D.

Third-party pen testing must be executed against the solution yearly with a pass rate of 80 percent or higher.

E.

The solution must provide the ability for users to view and track the progress of their requests.

F.

Management plane applications must return to operation (RTO) in under 10 minutes.

G.

The self service catalog must meet the Service Level Objective (SLO) of 75% successful requests measured over a 12 month period.

Question # 17

As part of a design for a VMware Cloud Foundation (VCF) solution, an architect has documented the following dependencies and constraints:

    CON001 - Internet access will not be permitted from anywhere within the VCF solution.

    CON002 - The password must not be stored in plain text anywhere within the VCF solution.

    DEP001 - The customer must make the required VCF binaries accessible to the VCF Installer appliance during the deployment phase.

Which design decision should the architect include in the design for the download of the VCF binaries for initial installation?

A.

The Offline Bundle Transfer Utility will be used on the VCF Installer appliance.

B.

The VCF Installer appliance will be configured to connect to an online depot.

C.

The VCF Installer appliance will be configured to connect to an offline depot.

D.

The VCF Download Tool will be used on the VCF Installer appliance.

Question # 18

An architect is designing a VMware Cloud Foundation (VCF) deployment for a customer transitioning to a hybrid cloud environment. The customer has provided the following requirements:

    Networking Capacity: The existing data center infrastructure includes 10 GbE switches and NICs, but the customer plans to upgrade to 25 GbE within the next 12 months to support higher throughput for management traffic, overlays, and future workload domains.

    Storage: The Management Domain must provide at least 15 TB of usable storage initially, with 20–30% headroom for organic growth in management components over the next 2 years. The customer prefers an all-flash configuration for performance.

    Growth: The deployment will start with the Management Domain and expand to include up to 2 additional Workload Domains within 18 months, requiring scalability in compute and storage without major redesign.

Based on the customer ' s requirements and VMware Cloud Foundation design guidelines, identify the key design decisions for the physical design of the VCF Management Domain.

Which three actions support the requirements for hosts, networking, storage, and growth? (Choose three.)

A.

Allow heterogeneous host configurations to leverage existing hardware inventory, as long as overall cluster capacity meets minimum thresholds.

B.

Equip each ESX host with dual 10 GbE NICs initially, ensuring support for Jumbo Frames (MTU 9000) and planning for a non-disruptive upgrade to 25 GbE NICs to align with future bandwidth needs.

C.

Implement vSAN ESA with an all-flash configuration, providing a minimum of 20 TB raw capacity across the cluster accounting for FTT=1, 30% vSAN overhead, and 20% growth reserve.

D.

Configure each ESX host with at least 22 physical CPU cores and 512 GB of RAM to accommodate the base management components plus resources for managing additional Workload Domains.

E.

Deploy a minimum of 3 ESX hosts in the Management Domain to optimize initial hardware costs while maintaining basic redundancy.

F.

Implement vSAN OSA with a hybrid configuration, providing a minimum of 20 TB raw capacity across the cluster accounting for FTT=1, 30% vSAN overhead, and 20% growth reserve, using at least 2 disk groups per host for performance and fault tolerance.

3V0-12.26 PDF

$27.5

$109.99

3 Months Free Update

  • Printable Format
  • Value of Money
  • 100% Pass Assurance
  • Verified Answers
  • Researched by Industry Experts
  • Based on Real Exams Scenarios
  • 100% Real Questions

3V0-12.26 PDF + Testing Engine

$44

$175.99

3 Months Free Update

  • Exam Name: Advanced VMware Cloud Foundation 9 Architect
  • Last Update: Oct 4, 2026
  • Questions and Answers: 60
  • Free Real Questions Demo
  • Recommended by Industry Experts
  • Best Economical Package
  • Immediate Access

3V0-12.26 Engine

$33

$131.99

3 Months Free Update

  • Best Testing Engine
  • One Click installation
  • Recommended by Teachers
  • Easy to use
  • 3 Modes of Learning
  • State of Art Technology
  • 100% Real Questions included