Summer Sale Coupon - 60% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: c4sbfdisc

5V0-21.21 PDF

$44

$109.99

3 Months Free Update

  • Printable Format
  • Value of Money
  • 100% Pass Assurance
  • Verified Answers
  • Researched by Industry Experts
  • Based on Real Exams Scenarios
  • 100% Real Questions

5V0-21.21 PDF + Testing Engine

$70.4

$175.99

3 Months Free Update

  • Exam Name: VMware HCI Master Specialist
  • Last Update: Apr 18, 2024
  • Questions and Answers: 66
  • Free Real Questions Demo
  • Recommended by Industry Experts
  • Best Economical Package
  • Immediate Access

5V0-21.21 Engine

$52.8

$131.99

3 Months Free Update

  • Best Testing Engine
  • One Click installation
  • Recommended by Teachers
  • Easy to use
  • 3 Modes of Learning
  • State of Art Technology
  • 100% Real Questions included

5V0-21.21 Practice Exam Questions with Answers VMware HCI Master Specialist Certification

Question # 6

An architect is designing a vSAN cluster where the hosts have more than 512 GB of memory.

Which two boot devices are recommended for these hosts? (Choose two.)

A.

USB

B.

PMEM

C.

SD

D.

Disk Device

E.

SATADOM

Full Access
Question # 7

An administrator wants to deploy Kubernetes on an end-to-end VMware stack, using VMware vSAN for storage.

Which VMware product should the administrator install as the Kubernetes platform choice?

A.

VMware Tanzu Kubernetes Grid

B.

VMware Tanzu Data services

C.

VMware Tanzu Build service

D.

VMware Tanzu Mission Control

Full Access
Question # 8

During a maintenance action on a vSAN node, a vSAN administrator noticed that the default repair delay time is about to be reached.

Which two commands must be run to extend the time? (Choose two.)

A.

/etc/init.d/vsanmgmtd restart

B.

esxcli system settings advanced set -o /VSAN/ClomRepairDelay -i 50

C.

esxcli system settings advanced set -o /VSAN/ClomRepairDelay -i 80

D.

/etc/init.d/clomd restart

E.

/etc/init.d/vsanobserver restart

Full Access
Question # 9

An administrator wants to enable encryption on an existing vSAN cluster that already contains virtual machines.

Which additional step should the administrator take to ensure no data is lost during the encryption process?

A.

Select ‘Erase disks before use’ check box when enabling encryption on a vSAN cluster.

B.

Make vCenter Server trust the KMS, either by trusting the KMS or by uploading a KMS certificate.

C.

Ensure that the vSAN Encryption is enabled by default on the existing cluster to encrypt old and new data.

D.

Disable vSphere Distributed Resources Schedule (DRS) on the vSAN cluster.

Full Access
Question # 10

An architect intends to use the Primary Level of Failures To Tolerate (PFTT) to calculate the minimum number of required hosts for a vSAN cluster.

Which calculation model should be used?

A.

1 * PFTT + 1

B.

2 * PFTT + 2

C.

1 * PFTT + 2

D.

2 * PFTT + 1

Full Access
Question # 11

An organization has two vSAN clusters managed by the same vCenter Server, each providing 100TB of storage. The first cluster runs at 75% of its storage capacity, and the second cluster runs at 50% of its storage capacity.

The company also has the following:

* An iSCSI array of 300TB. which runs at 76% of its capacity

* A NAS system of 200TB, which runs at 10% of its capacity

* A Fiber channel (FC) array of 300TB, which runs at 80% of its capacity

The administrator is asked to add an additional 25TB of storage to the first cluster. The administrator is also made aware that there is no budget to purchase new hardware and that the vSAN Storage Policy Based Management must be kept in place.

Which storage option will work for this use case?

A.

Create an HCI Mesh using the first cluster’s datastore.

B.

Obtain additional free capacity from the existing NAS storage.

C.

Obtain additional free capacity from the existing FC storage.

D.

Create an HCI Mesh using the second cluster’s datastore.

Full Access
Question # 12

As a part of a network hardware refresh project, all the network switches have been replaced with a newer, high-performance model. After the replacement, the company users started experiencing slowness on the applications hosted on their vSAN-backed VMs.

The vSAN administrator checked the vSAN Network Health status and noticed that the "Hosts large ping test" has failed.

What could be the cause of this performance degradation issue?

A.

MTU 9K is not configured on the hosts vSAN vMKernel ports.

B.

MTU 9K is not configured on the hosts VMnic ports.

C.

MTU 9K is not configured on the ToR switch.

D.

MTU 9K is not configured on the vDS switch.

Full Access
Question # 13

A customer is planning to migrate their physical Microsoft SQL Server clustered workloads to vSAN enabled vSphere clusters.

The following requirements must be met:

* Each MSSQL cluster is made up of 3 nodes

* Highest possible availability against node failures

* Some of the vSAN clusters will only consume storage

What should the architect recommend?

A.

vSAN iSCSI Target Service

B.

Stretched vSAN Cluster

C.

vSAN Direct

D.

vSAN File Services

Full Access
Question # 14

An administrator managing a vSAN cluster of six-nodes with policy FTT-2/RAID-6 decided to put one of the nodes in maintenance mode using the “Full-data migration” option.

What will happen after this action is taken?

A.

The host will enter in maintenance mode and the data will remain accessible until the host exits maintenance mode.

B.

The system will prompt to add an additional host to the cluster in order to preserve the policy compliance.

C.

The host will enter in maintenance mode and only data with no redundancy will remain accessible.

D.

The host will enter into maintenance mode if both components of a certain object are residing on that host, then one of the components will be moved to another available host.

Full Access
Question # 15

An administrator has received an alert indicating that a single capacity device is close to failing within the production vSAN Cluster. The administrator must now complete preemptive maintenance on the vSAN Cluster without impacting the availability of workloads or vSAN File Services.

The following information is known about the vSAN Cluster:

* vSAN 7.x Cluster

* vSAN node count: 8

* De-Duplication and Compression: Enabled.

* Encryption: Disabled

* Current Utilization: 45%

* Disk Groups: 2

* Devices per node: 2 x 400 GB SSD, 6 x 1.8 TB SSD

Which three steps should the administrator take to successfully complete the task? (Choose three.)

A.

Remove the affected Disk Group from the vSAN Cluster, and choose Full Data Migration.

B.

Replace the failed disk with a storage device that is identical in class and capacity.

C.

Remove the affected Disk Group from the vSAN Cluster, and choose No Data Migration.

D.

Replace the failed disk with a storage device that is identical in class but smaller in capacity.

E.

Put the affected vSAN host into maintenance mode to physically replace the storage device.

F.

Remove the affected Disk from the Disk Group, and choose Full Data Migration.

Full Access
Question # 16

An administrator has been tasked with enabling encryption for existing virtual machines on a vSAN cluster.

Which three prerequisites must be satisfied before completing the task? (Choose three.)

A.

Create an encryption storage policy

B.

Enable Data-In-Transit encryption first

C.

Enable that the virtual machines are powered on

D.

Verify if a role with privilege “Cryptographic operations.Encrypt new” is assigned

E.

Verify if a role with privilege “Cryptographic operations.Migrate” is assigned

F.

Establish a trusted connection with the KMS

Full Access
Question # 17

An administrator is planning to deploy cloud-native workloads onto the vSAN Direct datastore.

Which storage policy structure rule is supported?

A.

Host-based rules

B.

vVOL storage rules

C.

Tag-based placement rules

D.

Storage performance-based rules

Full Access
Question # 18

A company has deployed a 12-node (6-6-1) vSAN 7.0 stretched cluster for all production workloads.

The customer currently uses four different vSAN storage policies for running the workloads depending on the applications requirements:

* Policy 1 - Site Disaster Tolerance=Dual Site Mirroring, FTT=Erasure Coding

* Policy 2 - Site Disaster Tolerance=Dual Site Mirroring, FTT=Mirroring

* Policy 3 - Site Disaster Tolerance=None - Keep Data on Preferred, FTT=Mirroring

* Policy 4 - Site Disaster Tolerance=None - Keep Data on Non-Preferred, FTT=Mirroring

During the setup of the vSAN stretched cluster, the following VM/Host Rules were created:

* Preferred Site - Preferred Site workloads should run on DC1 hosts.

* Secondary Site - Secondary Site workloads should run on DC2 hosts.

Which two activities should the administrator complete to ensure that there is no impact to production services during the maintenance window in the Preferred Site? (Choose two.)

A.

Change the Site Disaster Tolerance setting in Policy 3 to be “Dual Site Mirroring”.

B.

Update vSphere DRS site affinity rules so that Preferred Site workloads should not run on hosts in DC1.

C.

Change the Site Disaster Tolerance setting in Policy 4 to be “None - Keep Data on Preferred”.

D.

Change the FTT setting in Policy 3 to be “Erasure Coding”.

E.

Update vSphere DRS site affinity rules so that Preferred Site workloads must run on hosts in DC2.

Full Access
Question # 19

A company hosts a vSAN 7 stretched cluster for all development workloads. The original sizing of a maximum of 250 concurrent workloads in the vSAN cluster is no longer sufficient and needs to increase to at least 500 concurrent workloads within the next six months.

To meet this demand, the original 8-node (4-4-1) cluster has recently been expanded to 16 nodes (8-8-1).

Which three additional steps should the administrator take to support the current growth plans while minimizing the amount of resources required at the witness site? (Choose three.)

A.

Add the new vSAN witness appliance to vCenter Server.

B.

Deploy a new large vSAN witness appliance at the witness site.

C.

Configure the vSAN stretched cluster to use the new vSAN witness.

D.

Deploy a new extra large vSAN witness appliance at the witness site.

E.

Upgrade the vSAN stretched cluster to vSAN 7.0 U1.

F.

Configure the new vSAN witness as a shared witness appliance.

Full Access